11:32 - Setting HVPA current limits... 11:32 - Finished task "Check high voltages" 11:32 - Starting task "Check high voltages" 11:32 - Found 0 drawer(s) in Nominal state, 0 in Low state and 61 in Wait state 11:33 - Actual voltage is between 147.62 V and 173.85 V. 11:33 - Low voltages range between 100.00 V and 100.00 V. 11:33 - Reference voltages range between 1400.00 V and 1400.00 V. 11:33 - Maximum difference between expected and actual voltages is 163.48 V 11:33 - Maximum of current limits is 5647.07 uA 11:33 - Checking status of HVPA module in 61 drawer(s)... 11:33 - Checking status of HVPA channels in 61 drawer(s)... 11:33 - HV is locked in 0 channel(s), was in rise default in 0 channel(s) and was still in progress in 427 channel(s) 11:33 - Checking reference voltages against 1400.00 V and low voltages against 100.00 V 11:33 - Done 11:33 - Finished task "Check high voltages" 12:23 - Resetting NMC 12:23 - Could not invoke the MethodCall service: BadDisconnect 12:23 - Starting task "Configure modules" 12:23 - The following monitored items could not be created: 0 12:23 - No server with URI='urn:UnifiedAutomation:UaServerCpp' has been discovered. The client could not discover a single server. 12:23 - Finished task "Configure modules" 12:23 - NMC is in state NmcState.Ready and knows of 0 drawer(s) 12:23 - Found 0 PPS errors. 12:23 - Starting task "Configure modules" 12:23 - Configuring modules with configuration /local/home/cta_test_bench/config/2019/20190801/config_61modules.NMC.xml 12:23 - Switching off high voltages in configuration 12:24 - Successfully configured 61 module(s) 12:24 - NMC is in state NmcState.Configured and knows of 61 drawer(s) 12:24 - Found PPS errors: 255 in drawer 128, 255 in drawer 129, 255 in drawer 130, 255 in drawer 131, 255 in drawer 132, 255 in drawer 133, 255 in drawer 134, 255 in drawer 135, 255 in drawer 136 12:24 - Finished task "Configure modules" 12:24 - Starting task "Set HV" 12:24 - Checking status of HVPA channels in 61 drawer(s)... 12:24 - HV is locked in 0 channel(s), was in rise default in 0 channel(s) and was still in progress in 427 channel(s) 12:24 - Setting HV to nominal values... 12:24 - Setting channel 0 voltages to [900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0] 12:24 - Setting channel 1 voltages to [900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0] 12:24 - Setting channel 2 voltages to [900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0] 12:24 - Setting channel 3 voltages to [900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0] 12:24 - Setting channel 4 voltages to [900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0] 12:24 - Setting channel 5 voltages to [900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0] 12:24 - Setting channel 6 voltages to [900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0, 900.0] 12:24 - Checking status of HVPA channels in 61 drawer(s)... 12:24 - HV is locked in 0 channel(s), was in rise default in 0 channel(s) and was still in progress in 427 channel(s) 12:25 - Finished task "Set HV" 12:25 - Checking status of calibration box... 12:25 - Calibration box is configured with 0 leds at a frequency of 16000000.0 Hz and a voltage of 7.90 V 12:25 - Starting task "Switch HVPA voltage state" 12:25 - Setting HVPA current limit to 12489.75 uA 12:26 - Setting HVPA ramp speed to 25 V/s 12:26 - Switching HVPA to state Nominal 12:26 - Configuring calibration box... 12:26 - Configuring calibration box with leds=0x318 voltage=10.00 frequency=2000.0/1 central_current=0.0 duration=0 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 12:26 - Setting HVPA current limits... 12:26 - Starting flashes... 12:27 - Finished task "Switch HVPA voltage state" 12:27 - Starting task "Check high voltages" 12:27 - Found 61 drawer(s) in Nominal state, 0 in Low state and 0 in Wait state 12:27 - High voltage locked channels will be checked every 30 s 12:27 - Actual voltage is between 899.14 V and 900.36 V. 12:27 - Low voltages range between 100.00 V and 100.00 V. 12:27 - Reference voltages range between 900.00 V and 900.00 V. 12:27 - Maximum difference between expected and actual voltages is 0.36 V 12:28 - Checking for high voltage locked pixels... 12:28 - Maximum of current limits is 5647.07 uA 12:28 - Checking status of HVPA module in 61 drawer(s)... 12:28 - Checking status of HVPA channels in 61 drawer(s)... 12:28 - HV is stabilized in all channels. 12:28 - Checking reference voltages against 900.00 V and low voltages against 100.00 V 12:28 - Done 12:28 - Finished task "Check high voltages" 12:28 - Checking for high voltage locked pixels... 12:29 - Checking for high voltage locked pixels... 12:29 - Stopping flashes... 12:29 - Checking for high voltage locked pixels... 12:30 - Checking for high voltage locked pixels... 12:30 - Checking for high voltage locked pixels... 12:31 - Checking for high voltage locked pixels... 12:31 - Checking for high voltage locked pixels... 12:32 - Checking for high voltage locked pixels... 12:32 - Starting NMC 12:32 - Clearing PPS error counters 12:32 - Checking for high voltage locked pixels... 12:32 - Configuring UCTS 12:32 - Configuring TIB... 12:32 - Setting TIB forced mode to False 12:32 - Writing False to Camera.TIB.Forced.ForcedMode.ForcedMode_v 12:32 - Status: TibState.PpsStopped 12:32 - Alarms: AlarmVector.ReadError 12:32 - Connection status: False 12:32 - Entering set_external_delay 12:32 - Setting ExternalDelayLocal to 0.000 ns 12:32 - Writing 0.0 to Camera.TIB.ExternalDelay.ExternalDelayLocal.ExternalDelayLocal_v 12:32 - Entering set_external_delay 12:32 - Setting ExternalDelayCalibration to 50.000 ns 12:32 - Writing 50.0 to Camera.TIB.ExternalDelay.ExternalDelayCalibration.ExternalDelayCalibration_v 12:32 - Entering set_external_delay 12:32 - Setting ExternalDelaySphe to 150.000 ns 12:32 - Writing 150.0 to Camera.TIB.ExternalDelay.ExternalDelaySphe.ExternalDelaySphe_v 12:32 - Setting TIB trigger mode to 0x78 = TriggerMask.SlowControl|Pedestal|Software|SPhE 12:32 - Writing 120 to Camera.TIB.TriggerMode.ModeMask.ModeMask_v 12:32 - Writing 0 to Camera.TIB.InputsEnable.InputMask.InputMask_v 12:32 - Writing False to Camera.TIB.BUSY.DisableBusy.DisableBusy_v 12:32 - Writing 0.0 to Camera.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 12:32 - Writing False to Camera.TIB.Throttler.DisableThrottler.DisableThrottler_v 12:32 - Writing 255 to Camera.TIB.Throttler.MaxTriggers50us.MaxTriggers50us_v 12:32 - Writing 255 to Camera.TIB.Throttler.MaxTriggers1ms.MaxTriggers1ms_v 12:32 - Status: TibState.PpsStopped 12:32 - Alarms: AlarmVector.ReadError 12:32 - Connection status: False 12:32 - Writing True to Camera.TIB.Pedestal.PeriodicPedestalEnable.PeriodicPedestalEnable_v 12:32 - Writing 500 to Camera.TIB.Pedestal.PeriodicPedestalFrequency.PeriodicPedestalFrequency_v 12:32 - Writing False to Camera.TIB.Pedestal.Fake_trig_enable.Fake_trig_enable_v 12:32 - Writing False to Camera.TIB.Pedestal.DigitalPedestalEnable.DigitalPedestalEnable_v 12:32 - Writing 500 to Camera.TIB.Pedestal.DigitalPedestal_config_Rate.DigitalPedestal_config_Rate_v 12:32 - Writing 375764 to Camera.TIB.Pedestal.DigitalPedestalSeed.DigitalPedestalSeed_v 12:32 - Writing False to Camera.TIB.Pedestal.Fake_trig_enable.Fake_trig_enable_v 12:32 - Writing False to Camera.TIB.Pedestal.AnalogPedestalEnable.AnalogPedestalEnable_v 12:32 - Writing 3000.0 to Camera.TIB.Pedestal.AnalogPedestalThreshold.AnalogPedestalThreshold_v 12:32 - Writing False to Camera.TIB.Pedestal.Fake_trig_enable.Fake_trig_enable_v 12:32 - Connecting TIB to camera server at 10.10.4.12:222 12:32 - Starting TIB... 12:32 - Status: TibState.PpsStopped 12:32 - Alarms: AlarmVector.ReadError 12:32 - Connection status: False 12:32 - Resetting run 12:32 - Wait for UCTS external trigger before enabling trigger... 12:32 - Status: TibState.Standby 12:32 - Alarms: AlarmVector.NoAlarm 12:32 - Connection status: False 12:32 - Status: TibState.Standby 12:32 - Alarms: AlarmVector.NoAlarm 12:32 - Connection status: False 12:32 - Status: TibState.Armed 12:32 - Alarms: AlarmVector.NoAlarm 12:32 - Connection status: True 12:33 - Checking for high voltage locked pixels... 12:33 - Starting TIB triggers... 12:33 - Enabling trigger 12:33 - Status: TibState.Running 12:33 - Alarms: AlarmVector.NoAlarm 12:33 - Connection status: True 2019-08-06 12:33:05,868 Creating OPC UA client of TIB at opc.tcp://10.10.4.64:48010 2019-08-06 12:33:05,875 Configuring calibration box with leds=0x318 voltage=10.00 frequency=2000/1 central_current=0 duration=0 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 2019-08-06 12:33:05,876 Calling method NectarCAM.CalibrationBox.Configure in object NectarCAM.CalibrationBox 2019-08-06 12:33:05,956 Moving XY table to position 0: module 79 2019-08-06 12:33:05,968 Module 79 is located at (X=-34.4 cm, Y=19.8 cm) in camera coordinates 2019-08-06 12:33:05,969 Module 79 is located at (X=118.4 cm, Y=113.8 cm) in XY table coordinates 2019-08-06 12:33:05,969 Moving XY table to position (Xtable=118.4 cm, Ytable=113.8 cm) 2019-08-06 12:33:05,969 Selecting XY table position: 118.4, 113.8 2019-08-06 12:33:05,973 Moving to next XY table position 2019-08-06 12:33:05,975 Waiting for XY table to be busy... 2019-08-06 12:33:06,864 XY table parking state changed to: False 2019-08-06 12:33:06,864 XY table busy state changed to: True 2019-08-06 12:33:06,867 XY table IS busy 2019-08-06 12:33:06,867 Waiting for XY table to be idle... 2019-08-06 12:33:18,866 XY table busy state changed to: False 2019-08-06 12:33:18,869 XY table is NOT busy 2019-08-06 12:33:18,872 Current position: (X=118.36 cm, Y=113.85 cm) in XY table coordinates 2019-08-06 12:33:18,877 Distance between expected and actual positions: 0.01 cm 2019-08-06 12:33:21,880 Starting SPE flasher 2019-08-06 12:33:21,880 Starting flashes... 2019-08-06 12:33:21,880 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:33:42,949 Stopping SPE flasher 2019-08-06 12:33:42,949 Stopping flashes... 2019-08-06 12:33:42,949 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:33:44,000 Triggering TIB by slow control 2019-08-06 12:33:44,000 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:33:44,003 Moving XY table to position 1: module 81 2019-08-06 12:33:44,014 Module 81 is located at (X=-34.4 cm, Y=-6.6 cm) in camera coordinates 2019-08-06 12:33:44,015 Module 81 is located at (X=118.4 cm, Y=87.4 cm) in XY table coordinates 2019-08-06 12:33:44,015 Moving XY table to position (Xtable=118.4 cm, Ytable=87.4 cm) 2019-08-06 12:33:44,015 Selecting XY table position: 118.4, 87.4 2019-08-06 12:33:44,019 Moving to next XY table position 2019-08-06 12:33:44,021 Waiting for XY table to be busy... 2019-08-06 12:33:44,868 XY table busy state changed to: True 2019-08-06 12:33:44,870 XY table IS busy 2019-08-06 12:33:44,870 Waiting for XY table to be idle... 2019-08-06 12:34:01,875 XY table busy state changed to: False 2019-08-06 12:34:01,878 XY table is NOT busy 2019-08-06 12:34:01,882 Current position: (X=118.37 cm, Y=87.39 cm) in XY table coordinates 2019-08-06 12:34:01,886 Distance between expected and actual positions: 0.01 cm 2019-08-06 12:34:04,888 Starting SPE flasher 2019-08-06 12:34:04,888 Starting flashes... 2019-08-06 12:34:04,888 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:34:25,958 Stopping SPE flasher 2019-08-06 12:34:25,958 Stopping flashes... 2019-08-06 12:34:25,958 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:34:27,009 Triggering TIB by slow control 2019-08-06 12:34:27,009 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:34:27,012 Moving XY table to position 2: module 83 2019-08-06 12:34:27,023 Module 83 is located at (X=-34.4 cm, Y=-33.1 cm) in camera coordinates 2019-08-06 12:34:27,024 Module 83 is located at (X=118.4 cm, Y=60.9 cm) in XY table coordinates 2019-08-06 12:34:27,024 Moving XY table to position (Xtable=118.4 cm, Ytable=60.9 cm) 2019-08-06 12:34:27,024 Selecting XY table position: 118.4, 60.9 2019-08-06 12:34:27,028 Moving to next XY table position 2019-08-06 12:34:27,029 Waiting for XY table to be busy... 2019-08-06 12:34:27,870 XY table busy state changed to: True 2019-08-06 12:34:27,873 XY table IS busy 2019-08-06 12:34:27,873 Waiting for XY table to be idle... 2019-08-06 12:34:44,872 XY table busy state changed to: False 2019-08-06 12:34:44,875 XY table is NOT busy 2019-08-06 12:34:44,879 Current position: (X=118.37 cm, Y=60.93 cm) in XY table coordinates 2019-08-06 12:34:44,883 Distance between expected and actual positions: 0.00 cm 2019-08-06 12:34:47,883 Starting SPE flasher 2019-08-06 12:34:47,883 Starting flashes... 2019-08-06 12:34:47,883 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:35:08,945 Stopping SPE flasher 2019-08-06 12:35:08,945 Stopping flashes... 2019-08-06 12:35:08,945 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:35:09,996 Triggering TIB by slow control 2019-08-06 12:35:09,996 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:35:09,999 Moving XY table to position 3: module 118 2019-08-06 12:35:10,011 Module 118 is located at (X=-11.5 cm, Y=-46.3 cm) in camera coordinates 2019-08-06 12:35:10,011 Module 118 is located at (X=95.5 cm, Y=47.7 cm) in XY table coordinates 2019-08-06 12:35:10,011 Moving XY table to position (Xtable=95.5 cm, Ytable=47.7 cm) 2019-08-06 12:35:10,011 Selecting XY table position: 95.5, 47.7 2019-08-06 12:35:10,016 Moving to next XY table position 2019-08-06 12:35:10,018 Waiting for XY table to be busy... 2019-08-06 12:35:10,874 XY table busy state changed to: True 2019-08-06 12:35:10,876 XY table IS busy 2019-08-06 12:35:10,876 Waiting for XY table to be idle... 2019-08-06 12:35:30,877 XY table busy state changed to: False 2019-08-06 12:35:30,879 XY table is NOT busy 2019-08-06 12:35:30,883 Current position: (X=95.45 cm, Y=47.70 cm) in XY table coordinates 2019-08-06 12:35:30,887 Distance between expected and actual positions: 0.01 cm 2019-08-06 12:35:33,890 Starting SPE flasher 2019-08-06 12:35:33,890 Starting flashes... 2019-08-06 12:35:33,890 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:35:54,961 Stopping SPE flasher 2019-08-06 12:35:54,961 Stopping flashes... 2019-08-06 12:35:54,961 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:35:56,012 Triggering TIB by slow control 2019-08-06 12:35:56,012 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:35:56,015 Moving XY table to position 4: module 116 2019-08-06 12:35:56,026 Module 116 is located at (X=-11.5 cm, Y=-19.8 cm) in camera coordinates 2019-08-06 12:35:56,027 Module 116 is located at (X=95.5 cm, Y=74.2 cm) in XY table coordinates 2019-08-06 12:35:56,027 Moving XY table to position (Xtable=95.5 cm, Ytable=74.2 cm) 2019-08-06 12:35:56,027 Selecting XY table position: 95.5, 74.2 2019-08-06 12:35:56,031 Moving to next XY table position 2019-08-06 12:35:56,033 Waiting for XY table to be busy... 2019-08-06 12:35:56,877 XY table busy state changed to: True 2019-08-06 12:35:56,880 XY table IS busy 2019-08-06 12:35:56,880 Waiting for XY table to be idle... 2019-08-06 12:36:13,878 XY table busy state changed to: False 2019-08-06 12:36:13,880 XY table is NOT busy 2019-08-06 12:36:13,884 Current position: (X=95.46 cm, Y=74.16 cm) in XY table coordinates 2019-08-06 12:36:13,888 Distance between expected and actual positions: 0.00 cm 2019-08-06 12:36:16,891 Starting SPE flasher 2019-08-06 12:36:16,891 Starting flashes... 2019-08-06 12:36:16,891 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:36:37,962 Stopping SPE flasher 2019-08-06 12:36:37,962 Stopping flashes... 2019-08-06 12:36:37,962 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:36:39,012 Triggering TIB by slow control 2019-08-06 12:36:39,013 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:36:39,016 Moving XY table to position 5: module 114 2019-08-06 12:36:39,027 Module 114 is located at (X=-11.5 cm, Y=6.6 cm) in camera coordinates 2019-08-06 12:36:39,027 Module 114 is located at (X=95.5 cm, Y=100.6 cm) in XY table coordinates 2019-08-06 12:36:39,028 Moving XY table to position (Xtable=95.5 cm, Ytable=100.6 cm) 2019-08-06 12:36:39,028 Selecting XY table position: 95.5, 100.6 2019-08-06 12:36:39,032 Moving to next XY table position 2019-08-06 12:36:39,034 Waiting for XY table to be busy... 2019-08-06 12:36:39,880 XY table busy state changed to: True 2019-08-06 12:36:39,882 XY table IS busy 2019-08-06 12:36:39,882 Waiting for XY table to be idle... 2019-08-06 12:36:56,879 XY table busy state changed to: False 2019-08-06 12:36:56,882 XY table is NOT busy 2019-08-06 12:36:56,885 Current position: (X=95.46 cm, Y=100.61 cm) in XY table coordinates 2019-08-06 12:36:56,889 Distance between expected and actual positions: 0.00 cm 2019-08-06 12:36:59,892 Starting SPE flasher 2019-08-06 12:36:59,892 Starting flashes... 2019-08-06 12:36:59,893 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:37:20,960 Stopping SPE flasher 2019-08-06 12:37:20,961 Stopping flashes... 2019-08-06 12:37:20,961 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:37:22,012 Triggering TIB by slow control 2019-08-06 12:37:22,012 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:37:22,015 Moving XY table to position 6: module 112 2019-08-06 12:37:22,026 Module 112 is located at (X=-11.5 cm, Y=33.1 cm) in camera coordinates 2019-08-06 12:37:22,027 Module 112 is located at (X=95.5 cm, Y=127.1 cm) in XY table coordinates 2019-08-06 12:37:22,027 Moving XY table to position (Xtable=95.5 cm, Ytable=127.1 cm) 2019-08-06 12:37:22,027 Selecting XY table position: 95.5, 127.1 2019-08-06 12:37:22,031 Moving to next XY table position 2019-08-06 12:37:22,033 Waiting for XY table to be busy... 2019-08-06 12:37:22,881 XY table busy state changed to: True 2019-08-06 12:37:22,884 XY table IS busy 2019-08-06 12:37:22,884 Waiting for XY table to be idle... 2019-08-06 12:37:39,881 XY table busy state changed to: False 2019-08-06 12:37:39,883 XY table is NOT busy 2019-08-06 12:37:39,887 Current position: (X=95.46 cm, Y=127.07 cm) in XY table coordinates 2019-08-06 12:37:39,891 Distance between expected and actual positions: 0.00 cm 2019-08-06 12:37:42,893 Starting SPE flasher 2019-08-06 12:37:42,893 Starting flashes... 2019-08-06 12:37:42,893 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:38:03,963 Stopping SPE flasher 2019-08-06 12:38:03,963 Stopping flashes... 2019-08-06 12:38:03,963 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:38:05,014 Triggering TIB by slow control 2019-08-06 12:38:05,014 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:38:05,018 Moving XY table to position 7: module 146 2019-08-06 12:38:05,029 Module 146 is located at (X=11.5 cm, Y=46.3 cm) in camera coordinates 2019-08-06 12:38:05,030 Module 146 is located at (X=72.5 cm, Y=140.3 cm) in XY table coordinates 2019-08-06 12:38:05,030 Moving XY table to position (Xtable=72.5 cm, Ytable=140.3 cm) 2019-08-06 12:38:05,030 Selecting XY table position: 72.5, 140.3 2019-08-06 12:38:05,034 Moving to next XY table position 2019-08-06 12:38:05,036 Waiting for XY table to be busy... 2019-08-06 12:38:05,882 XY table busy state changed to: True 2019-08-06 12:38:05,884 XY table IS busy 2019-08-06 12:38:05,884 Waiting for XY table to be idle... 2019-08-06 12:38:25,884 XY table busy state changed to: False 2019-08-06 12:38:25,886 XY table is NOT busy 2019-08-06 12:38:25,890 Current position: (X=72.54 cm, Y=140.30 cm) in XY table coordinates 2019-08-06 12:38:25,894 Distance between expected and actual positions: 0.01 cm 2019-08-06 12:38:28,897 Starting SPE flasher 2019-08-06 12:38:28,897 Starting flashes... 2019-08-06 12:38:28,897 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:38:49,970 Stopping SPE flasher 2019-08-06 12:38:49,970 Stopping flashes... 2019-08-06 12:38:49,970 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:38:51,022 Triggering TIB by slow control 2019-08-06 12:38:51,022 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:38:51,025 Moving XY table to position 8: module 148 2019-08-06 12:38:51,036 Module 148 is located at (X=11.5 cm, Y=19.8 cm) in camera coordinates 2019-08-06 12:38:51,037 Module 148 is located at (X=72.5 cm, Y=113.8 cm) in XY table coordinates 2019-08-06 12:38:51,037 Moving XY table to position (Xtable=72.5 cm, Ytable=113.8 cm) 2019-08-06 12:38:51,037 Selecting XY table position: 72.5, 113.8 2019-08-06 12:38:51,041 Moving to next XY table position 2019-08-06 12:38:51,043 Waiting for XY table to be busy... 2019-08-06 12:38:51,885 XY table busy state changed to: True 2019-08-06 12:38:51,888 XY table IS busy 2019-08-06 12:38:51,888 Waiting for XY table to be idle... 2019-08-06 12:39:08,886 XY table busy state changed to: False 2019-08-06 12:39:08,889 XY table is NOT busy 2019-08-06 12:39:08,892 Current position: (X=72.54 cm, Y=113.85 cm) in XY table coordinates 2019-08-06 12:39:08,896 Distance between expected and actual positions: 0.01 cm 2019-08-06 12:39:11,897 Starting SPE flasher 2019-08-06 12:39:11,897 Starting flashes... 2019-08-06 12:39:11,897 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:39:32,968 Stopping SPE flasher 2019-08-06 12:39:32,968 Stopping flashes... 2019-08-06 12:39:32,968 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:39:34,019 Triggering TIB by slow control 2019-08-06 12:39:34,020 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:39:34,023 Moving XY table to position 9: module 150 2019-08-06 12:39:34,034 Module 150 is located at (X=11.5 cm, Y=-6.6 cm) in camera coordinates 2019-08-06 12:39:34,034 Module 150 is located at (X=72.5 cm, Y=87.4 cm) in XY table coordinates 2019-08-06 12:39:34,034 Moving XY table to position (Xtable=72.5 cm, Ytable=87.4 cm) 2019-08-06 12:39:34,034 Selecting XY table position: 72.5, 87.4 2019-08-06 12:39:34,039 Moving to next XY table position 2019-08-06 12:39:34,041 Waiting for XY table to be busy... 2019-08-06 12:39:34,888 XY table busy state changed to: True 2019-08-06 12:39:34,891 XY table IS busy 2019-08-06 12:39:34,891 Waiting for XY table to be idle... 2019-08-06 12:39:51,892 XY table busy state changed to: False 2019-08-06 12:39:51,894 XY table is NOT busy 2019-08-06 12:39:51,898 Current position: (X=72.54 cm, Y=87.39 cm) in XY table coordinates 2019-08-06 12:39:51,902 Distance between expected and actual positions: 0.01 cm 2019-08-06 12:39:54,904 Starting SPE flasher 2019-08-06 12:39:54,904 Starting flashes... 2019-08-06 12:39:54,904 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:40:15,975 Stopping SPE flasher 2019-08-06 12:40:15,975 Stopping flashes... 2019-08-06 12:40:15,975 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:40:17,027 Triggering TIB by slow control 2019-08-06 12:40:17,027 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:40:17,030 Moving XY table to position 10: module 152 2019-08-06 12:40:17,042 Module 152 is located at (X=11.5 cm, Y=-33.1 cm) in camera coordinates 2019-08-06 12:40:17,042 Module 152 is located at (X=72.5 cm, Y=60.9 cm) in XY table coordinates 2019-08-06 12:40:17,042 Moving XY table to position (Xtable=72.5 cm, Ytable=60.9 cm) 2019-08-06 12:40:17,042 Selecting XY table position: 72.5, 60.9 2019-08-06 12:40:17,047 Moving to next XY table position 2019-08-06 12:40:17,049 Waiting for XY table to be busy... 2019-08-06 12:40:17,894 XY table busy state changed to: True 2019-08-06 12:40:17,897 XY table IS busy 2019-08-06 12:40:17,897 Waiting for XY table to be idle... 2019-08-06 12:40:34,897 XY table busy state changed to: False 2019-08-06 12:40:34,899 XY table is NOT busy 2019-08-06 12:40:34,903 Current position: (X=72.54 cm, Y=60.93 cm) in XY table coordinates 2019-08-06 12:40:34,907 Distance between expected and actual positions: 0.00 cm 2019-08-06 12:40:37,910 Starting SPE flasher 2019-08-06 12:40:37,910 Starting flashes... 2019-08-06 12:40:37,910 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:40:58,977 Stopping SPE flasher 2019-08-06 12:40:58,977 Stopping flashes... 2019-08-06 12:40:58,977 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:41:00,028 Triggering TIB by slow control 2019-08-06 12:41:00,028 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:41:00,031 Moving XY table to position 11: module 185 2019-08-06 12:41:00,043 Module 185 is located at (X=34.4 cm, Y=-19.8 cm) in camera coordinates 2019-08-06 12:41:00,043 Module 185 is located at (X=49.6 cm, Y=74.2 cm) in XY table coordinates 2019-08-06 12:41:00,043 Moving XY table to position (Xtable=49.6 cm, Ytable=74.2 cm) 2019-08-06 12:41:00,043 Selecting XY table position: 49.6, 74.2 2019-08-06 12:41:00,047 Moving to next XY table position 2019-08-06 12:41:00,049 Waiting for XY table to be busy... 2019-08-06 12:41:00,899 XY table busy state changed to: True 2019-08-06 12:41:00,901 XY table IS busy 2019-08-06 12:41:00,901 Waiting for XY table to be idle... 2019-08-06 12:41:21,900 XY table busy state changed to: False 2019-08-06 12:41:21,903 XY table is NOT busy 2019-08-06 12:41:21,907 Current position: (X=49.62 cm, Y=74.15 cm) in XY table coordinates 2019-08-06 12:41:21,910 Distance between expected and actual positions: 0.01 cm 2019-08-06 12:41:24,913 Starting SPE flasher 2019-08-06 12:41:24,913 Starting flashes... 2019-08-06 12:41:24,913 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:41:45,983 Stopping SPE flasher 2019-08-06 12:41:45,983 Stopping flashes... 2019-08-06 12:41:45,983 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:41:47,034 Triggering TIB by slow control 2019-08-06 12:41:47,035 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:41:47,038 Moving XY table to position 12: module 183 2019-08-06 12:41:47,049 Module 183 is located at (X=34.4 cm, Y=6.6 cm) in camera coordinates 2019-08-06 12:41:47,049 Module 183 is located at (X=49.6 cm, Y=100.6 cm) in XY table coordinates 2019-08-06 12:41:47,050 Moving XY table to position (Xtable=49.6 cm, Ytable=100.6 cm) 2019-08-06 12:41:47,050 Selecting XY table position: 49.6, 100.6 2019-08-06 12:41:47,053 Moving to next XY table position 2019-08-06 12:41:47,055 Waiting for XY table to be busy... 2019-08-06 12:41:47,902 XY table busy state changed to: True 2019-08-06 12:41:47,904 XY table IS busy 2019-08-06 12:41:47,904 Waiting for XY table to be idle... 2019-08-06 12:42:04,902 XY table busy state changed to: False 2019-08-06 12:42:04,904 XY table is NOT busy 2019-08-06 12:42:04,908 Current position: (X=49.63 cm, Y=100.61 cm) in XY table coordinates 2019-08-06 12:42:04,912 Distance between expected and actual positions: 0.00 cm 2019-08-06 12:42:07,915 Starting SPE flasher 2019-08-06 12:42:07,915 Starting flashes... 2019-08-06 12:42:07,915 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:42:28,986 Stopping SPE flasher 2019-08-06 12:42:28,986 Stopping flashes... 2019-08-06 12:42:28,986 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:42:30,036 Triggering TIB by slow control 2019-08-06 12:42:30,036 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:42:30,039 Moving XY table to position 13: module 181 2019-08-06 12:42:30,051 Module 181 is located at (X=34.4 cm, Y=33.1 cm) in camera coordinates 2019-08-06 12:42:30,051 Module 181 is located at (X=49.6 cm, Y=127.1 cm) in XY table coordinates 2019-08-06 12:42:30,051 Moving XY table to position (Xtable=49.6 cm, Ytable=127.1 cm) 2019-08-06 12:42:30,051 Selecting XY table position: 49.6, 127.1 2019-08-06 12:42:30,055 Moving to next XY table position 2019-08-06 12:42:30,057 Waiting for XY table to be busy... 2019-08-06 12:42:30,902 XY table busy state changed to: True 2019-08-06 12:42:30,904 XY table IS busy 2019-08-06 12:42:30,904 Waiting for XY table to be idle... 2019-08-06 12:42:47,904 XY table busy state changed to: False 2019-08-06 12:42:47,906 XY table is NOT busy 2019-08-06 12:42:47,910 Current position: (X=49.63 cm, Y=127.07 cm) in XY table coordinates 2019-08-06 12:42:47,914 Distance between expected and actual positions: 0.00 cm 2019-08-06 12:42:50,916 Starting SPE flasher 2019-08-06 12:42:50,916 Starting flashes... 2019-08-06 12:42:50,916 Calling method NectarCAM.CalibrationBox.Start in object NectarCAM.CalibrationBox 2019-08-06 12:43:11,980 Stopping SPE flasher 2019-08-06 12:43:11,980 Stopping flashes... 2019-08-06 12:43:11,980 Calling method NectarCAM.CalibrationBox.Stop in object NectarCAM.CalibrationBox 2019-08-06 12:43:13,031 Triggering TIB by slow control 2019-08-06 12:43:13,031 Calling method Camera.TIB.LaunchSCTrigger in object Camera.TIB 2019-08-06 12:43:13,034 Moving white target to parking position 2019-08-06 12:43:13,036 Waiting for parked position... 2019-08-06 12:43:13,907 XY table busy state changed to: True 2019-08-06 12:43:45,910 XY table busy state changed to: False 2019-08-06 12:43:45,910 XY table parking state changed to: True 2019-08-06 12:43:45,912 XY table IS parked 12:33 - Checking for high voltage locked pixels... 12:34 - Checking for high voltage locked pixels... 12:34 - Checking for high voltage locked pixels... 12:35 - Checking for high voltage locked pixels... 12:35 - Checking for high voltage locked pixels... 12:36 - Checking for high voltage locked pixels... 12:36 - Checking for high voltage locked pixels... 12:37 - Checking for high voltage locked pixels... 12:37 - Checking for high voltage locked pixels... 12:38 - Checking for high voltage locked pixels... 12:38 - Checking for high voltage locked pixels... 12:39 - Checking for high voltage locked pixels... 12:39 - Checking for high voltage locked pixels... 12:40 - Checking for high voltage locked pixels... 12:40 - Checking for high voltage locked pixels... 12:41 - Checking for high voltage locked pixels... 12:41 - Checking for high voltage locked pixels... 12:42 - Checking for high voltage locked pixels... 12:42 - Checking for high voltage locked pixels... 12:43 - Checking for high voltage locked pixels... 12:43 - Stopping TIB... 12:43 - Status: TibState.Running 12:43 - Alarms: AlarmVector.ReadError 12:43 - Connection status: True 12:43 - Disabling trigger 12:43 - Disabling PPS 12:43 - Status: TibState.PpsStopped 12:43 - Alarms: AlarmVector.ReadError 12:43 - Connection status: True 12:43 - Closing TIB connection to camera server 12:43 - Status: TibState.PpsStopped 12:43 - Alarms: AlarmVector.ReadError 12:43 - Connection status: False 12:43 - Run duration: 0:10:17 12:43 - Local camera triggers: 0 12:43 - Slow control triggers: 14 12:43 - Single photo-electron triggers: 589915 12:43 - Calibration triggers: 616168 12:43 - Software triggers from UCTS: 0 12:43 - Pedestal triggers: 308044 12:43 - Collected input triggers: 895757 12:43 - Busy triggers: 4198 12:43 - Camera event triggers sent to clusters: 891559