14:44 - Starting task "Check high voltages" 14:44 - Found 0 drawer(s) in Nominal state, 0 in Low state and 61 in Wait state 14:44 - Actual voltage is between 0.00 V and 6.10 V. 14:44 - Low voltages range between 100.00 V and 100.00 V. 14:44 - Reference voltages range between 948.03 V and 1172.93 V. 14:44 - Maximum difference between expected and actual voltages is 6.71 V 14:44 - Maximum of current limits is 5647.07 uA 14:44 - Checking status of HVPA module in 61 drawer(s)... 14:44 - Checking status of HVPA channels in 61 drawer(s)... 14:44 - HV is locked in 0 channel(s), was in rise default in 0 channel(s) and was still in progress in 427 channel(s) 14:44 - Checking reference and low voltages against /local/home/cta_test_bench/config/2019/20190315/NectarCAM_Run1108_newL1A.NMC.xml 14:45 - Done 14:45 - Finished task "Configure modules" 14:45 - Starting task "Configure modules" 14:45 - Configuring modules with configuration /local/home/cta_test_bench/config/2019/20190315/NectarCAM.Run1117.NMC.xml 14:45 - Could not invoke the MethodCall service: BadTimeout 14:45 - Resetting NMC 14:46 - Could not invoke the MethodCall service: BadTimeout 14:45 - Could not invoke the Read service: BadTimeout 14:45 - Finished task "Configure modules" 14:46 - Resetting NMC 14:46 - Could not invoke the MethodCall service: BadTimeout 14:48 - Starting task "Configure modules" 14:48 - Configuring modules with configuration /local/home/cta_test_bench/config/2019/20190315/NectarCAM.Run1117.NMC.xml 14:48 - Successfully configured 61 module(s) 14:48 - NMC is in state NmcState.Configured and knows of 61 drawer(s) 14:48 - Found 0 PPS errors. 14:48 - Finished task "Configure modules" 14:48 - Starting task "Switch HVPA voltage state" 14:48 - Setting HVPA current limit to 12489.75 uA 14:49 - Setting HVPA ramp speed to 35 V/s 14:49 - Switching HVPA to state Nominal 14:49 - Setting HVPA current limits... 14:49 - Finished task "Switch HVPA voltage state" 14:50 - Starting task "Check high voltages" 14:50 - Found 61 drawer(s) in Nominal state, 0 in Low state and 0 in Wait state 14:50 - Actual voltage is between 14.64 V and 1172.42 V. 14:50 - Low voltages range between 100.00 V and 100.00 V. 14:50 - Reference voltages range between 0.00 V and 1172.15 V. 14:50 - Maximum difference between expected and actual voltages is 18.91 V 14:50 - Maximum of current limits is 5647.07 uA 14:50 - Checking status of HVPA module in 61 drawer(s)... 14:50 - HVPA module in drawer 81 has a status of 0x3f! 14:50 - HVPA module in drawer 146 has a status of 0x7d! 14:50 - HVPA module in drawer 163 has a status of 0x77! 14:50 - Checking status of HVPA channels in 61 drawer(s)... 14:50 - HVPA channel 1 of drawer 146 has status 0x8003! 14:50 - HVPA channel 3 of drawer 163 has status 0x8003! 14:50 - HVPA channel 6 of drawer 81 has status 0x8003! 14:50 - HV is locked in 3 channel(s), was in rise default in 0 channel(s) and was still in progress in 0 channel(s) 14:50 - Resetting 3 channel(s)... 14:50 - Resetting HVPA channel 1 of drawer 146... 14:50 - Resetting HVPA channel 3 of drawer 163... 14:50 - Resetting HVPA channel 6 of drawer 81... 14:50 - Checking reference and low voltages against /local/home/cta_test_bench/config/2019/20190315/NectarCAM.Run1117.NMC.xml 14:50 - Done 14:50 - Finished task "Check high voltages" 14:51 - Starting task "Check high voltages" 14:51 - Found 61 drawer(s) in Nominal state, 0 in Low state and 0 in Wait state 14:51 - Actual voltage is between 947.94 V and 1172.42 V. 14:51 - Low voltages range between 100.00 V and 100.00 V. 14:51 - Reference voltages range between 948.03 V and 1172.15 V. 14:52 - Maximum difference between expected and actual voltages is 0.72 V 14:52 - Maximum of current limits is 5647.07 uA 14:52 - Checking status of HVPA module in 61 drawer(s)... 14:52 - Checking status of HVPA channels in 61 drawer(s)... 14:52 - HV is locked in 0 channel(s), was in rise default in 0 channel(s) and was still in progress in 1 channel(s) 14:52 - Checking reference and low voltages against /local/home/cta_test_bench/config/2019/20190315/NectarCAM.Run1117.NMC.xml 14:52 - Done 14:52 - Finished task "Check high voltages" 14:52 - Starting NMC 14:52 - Clearing PPS error counters 14:56 - Configuring UCTS 14:56 - Configuring TIB... 14:56 - Setting TIB forced mode to False 14:56 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 14:56 - Status: TibState.PpsStopped 14:56 - Alarms: AlarmVector.NoAlarm 14:56 - Connection status: False 14:56 - Entering set_external_delay 14:56 - Setting ExternalDelayLocal to 0.000 ns 14:56 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelayLocal.ExternalDelayLocal_v 14:56 - Failed to write 'serveur.TIB.ExternalDelay.ExternalDelayLocal.ExternalDelayLocal_v': - overallStatus : Bad statuses are present - requestHandle : 7 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 14:56 - Writing 56.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 14:56 - Setting TIB trigger mode to 0x58 = TriggerMask.SlowControl|Software|SPhE 14:56 - Writing 88 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 14:56 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 14:56 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 14:56 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 14:56 - Writing False to serveur.TIB.Throttler.DisableThrottler.DisableThrottler_v 14:56 - Failed to write 'serveur.TIB.Throttler.DisableThrottler.DisableThrottler_v': - overallStatus : Bad statuses are present - requestHandle : 19 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 14:56 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 14:56 - Writing False to serveur.TIB.Throttler.DisableThrottlerWR.DisableThrottlerWR_v 14:56 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 14:56 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR50us.MaxTriggersWR50us_v 14:56 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 14:56 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR1ms.MaxTriggersWR1ms_v 14:56 - Status: TibState.PpsStopped 14:56 - Alarms: AlarmVector.NoAlarm 14:56 - Connection status: False 14:56 - Writing True to serveur.TIB.Pedestal.PeriodicPedestalEnable.PeriodicPedestalEnable_v 14:56 - Failed to write 'serveur.TIB.Pedestal.PeriodicPedestalEnable.PeriodicPedestalEnable_v': - overallStatus : Bad statuses are present - requestHandle : 35 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 14:57 - Connecting TIB to camera server at 10.10.4.12:222 14:57 - Starting TIB... 14:57 - Status: TibState.PpsStopped 14:57 - Alarms: AlarmVector.NoAlarm 14:57 - Connection status: True 14:57 - Resetting run 14:57 - Wait for UCTS external trigger before enabling trigger... 14:57 - Status: TibState.Standby 14:57 - Alarms: AlarmVector.NoAlarm 14:57 - Connection status: True 14:57 - Status: TibState.Standby 14:57 - Alarms: AlarmVector.NoAlarm 14:57 - Connection status: True 14:57 - Status: TibState.Armed 14:57 - Alarms: AlarmVector.NoAlarm 14:57 - Connection status: True 14:58 - Starting TIB triggers... 14:58 - Enabling trigger 14:58 - Status: TibState.Running 14:58 - Alarms: AlarmVector.NoAlarm 14:58 - Connection status: True 15:00 - NMC is in state NmcState.Running and knows of 61 drawer(s) 15:00 - Found 0 PPS errors. 15:02 - Configuring calibration box... 15:02 - Configuring calibration box with leds=0x1fff voltage=16.00 frequency=1000.0/1 central_current=0.0 duration=110 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 15:02 - Starting flashes... 15:02 - Stopping TIB... 15:02 - Status: TibState.Running 15:02 - Alarms: AlarmVector.NoAlarm 15:02 - Connection status: True 15:02 - Disabling trigger 15:02 - Disabling PPS 15:02 - Status: TibState.PpsStopped 15:02 - Alarms: AlarmVector.NoAlarm 15:02 - Connection status: True 15:02 - Closing TIB connection to camera server 15:02 - Status: TibState.PpsStopped 15:02 - Alarms: AlarmVector.NoAlarm 15:02 - Connection status: False 15:02 - Run duration: 0:05:23 15:02 - Local camera triggers: 0 15:02 - Slow control triggers: 0 15:02 - Single photo-electron triggers: 10961 15:02 - Calibration triggers: 0 15:02 - Software triggers from UCTS: 0 15:02 - Pedestal triggers: 2097781 15:02 - Collected input triggers: 10961 15:02 - Busy triggers: 0 15:02 - Camera event triggers sent to clusters: 10961 15:03 - Stopping NMC 15:03 - Found 0 PPS errors. 15:03 - Starting task "Check high voltages" 15:03 - Found 61 drawer(s) in Nominal state, 0 in Low state and 0 in Wait state 15:03 - Actual voltage is between 947.94 V and 1172.42 V. 15:03 - Low voltages range between 100.00 V and 100.00 V. 15:03 - Reference voltages range between 948.03 V and 1172.15 V. 15:03 - Maximum difference between expected and actual voltages is 0.96 V