14:54 - Starting task "Set HV" 14:54 - Checking status of HVPA channels in 61 drawer(s)... 14:54 - HV is stabilized in all channels. 14:54 - Setting HV to nominal values... 14:55 - Starting task "Set HV" 14:55 - Checking status of HVPA channels in 61 drawer(s)... 14:55 - HV is stabilized in all channels. 14:55 - Setting HV to nominal values... 14:55 - Setting channel 0 voltages to [1076.82, 1066.25, 1041.83, 1056.87, 1005.68, 1054.37, 1032.36, 1057.51, 1028.63, 1034.77, 1041.43, 1057.37, 1096.42, 1123.82, 1004.57, 1021.82, 993.59, 1024.74, 1010.43, 1006.51, 1022.4, 1034.82, 1082.24, 1032.75, 994.0, 1022.72, 1057.32, 1005.62, 1000.41, 1019.5, 968.34, 1122.98, 1076.17, 1070.59, 1131.43, 1003.7, 1072.41, 1039.06, 1117.58, 1023.67, 1098.49, 1057.17, 1004.51, 1079.85, 989.08, 970.44, 1048.28, 1034.66, 954.05, 1031.53, 990.26, 1011.58, 1052.31, 1014.91, 1010.84, 1024.55, 1034.21, 1047.61, 1044.9, 998.0, 1022.87] 14:55 - Setting channel 1 voltages to [1129.61, 1043.43, 1059.34, 1059.72, 1020.64, 958.08, 1017.09, 1054.53, 1029.01, 1037.95, 1023.45, 1097.78, 1008.11, 1098.64, 1015.07, 1055.93, 1043.86, 1163.51, 1076.1, 1002.25, 1006.5, 1113.11, 1051.26, 1039.79, 1012.24, 1003.35, 962.02, 1068.76, 1065.67, 1013.97, 1024.49, 1090.2, 1066.94, 1064.92, 991.07, 1125.34, 1009.62, 1092.35, 1136.31, 1001.03, 1036.08, 1074.19, 1021.42, 1022.83, 1053.09, 1028.91, 1048.27, 974.68, 997.6, 1060.92, 1013.85, 1039.14, 1026.62, 973.83, 981.36, 975.49, 993.35, 1011.83, 1053.45, 976.24, 1018.18] 14:55 - Setting channel 2 voltages to [1086.54, 1065.96, 1062.25, 1047.68, 990.84, 1020.49, 983.32, 1108.49, 1025.09, 1000.07, 1117.69, 1068.64, 1051.51, 983.2, 1005.52, 1050.61, 1025.0, 1107.17, 978.42, 1026.67, 1022.82, 1010.48, 1154.04, 1032.26, 1072.74, 976.96, 973.09, 1079.04, 1058.81, 999.73, 1025.17, 1154.86, 1057.23, 1023.92, 1058.12, 971.0, 977.81, 969.51, 992.45, 1065.81, 1034.88, 1101.98, 1157.55, 1021.61, 1015.23, 998.45, 1088.62, 984.81, 1027.33, 1030.11, 1013.0, 1026.0, 1024.09, 995.74, 983.19, 960.6, 958.06, 1001.62, 1076.89, 1012.86, 1052.16] 14:55 - Setting channel 3 voltages to [1033.49, 1099.74, 1073.87, 1042.28, 981.53, 1021.91, 1100.77, 984.84, 1077.47, 1150.89, 1088.99, 1141.56, 989.12, 1018.94, 1024.15, 1018.68, 1065.84, 1117.41, 1029.82, 1050.16, 1014.9, 1040.37, 1102.66, 995.67, 1051.46, 1002.71, 1092.54, 1027.08, 976.42, 1044.52, 1079.17, 1073.44, 1136.2, 1034.67, 1062.35, 984.3, 992.66, 1041.47, 1091.28, 1045.15, 1094.16, 1046.17, 1009.65, 1063.48, 1018.2, 977.98, 1047.36, 1119.3, 1110.19, 1057.69, 1108.09, 1003.5, 1033.38, 1004.33, 996.84, 953.8, 1013.12, 1036.36, 1041.21, 1100.53, 1021.47] 14:55 - Setting channel 4 voltages to [994.18, 964.27, 1084.26, 976.32, 1080.34, 975.66, 983.7, 1029.28, 1016.11, 1092.9, 1061.52, 1116.74, 1054.42, 1021.46, 1038.74, 997.06, 1070.86, 1044.38, 1095.59, 1046.85, 1056.42, 1044.54, 1103.83, 1010.42, 976.09, 998.02, 962.4, 1042.69, 983.17, 1035.15, 1080.25, 1064.72, 1097.44, 1055.14, 976.85, 1005.99, 1031.36, 1088.57, 1090.65, 1052.88, 1070.43, 1064.96, 1083.02, 1036.14, 1003.91, 1000.85, 1100.48, 1024.98, 1024.85, 985.41, 1086.32, 1083.68, 1044.71, 994.68, 1036.9, 1009.89, 998.17, 983.55, 1049.01, 1074.87, 1068.61] 14:55 - Setting channel 5 voltages to [1136.84, 1172.15, 1032.07, 1041.38, 998.16, 989.36, 1102.59, 1062.67, 1060.5, 1072.3, 1076.85, 1102.53, 1106.73, 981.26, 1016.71, 1033.94, 1067.21, 991.51, 1006.97, 1031.66, 1124.27, 1014.77, 1074.93, 1030.49, 1039.17, 1068.79, 1003.41, 1044.42, 1032.46, 972.28, 1050.16, 1104.28, 1044.32, 1017.01, 1053.06, 1023.16, 1012.38, 1011.66, 1139.49, 1008.49, 1069.62, 1034.0, 1023.27, 1067.71, 1021.77, 1087.77, 1032.45, 991.25, 1047.77, 1071.0, 1035.2, 1136.17, 1028.81, 1047.66, 1009.57, 993.25, 1042.64, 1036.88, 997.22, 1018.02, 1059.36] 14:55 - Setting channel 6 voltages to [1067.66, 1001.3, 1164.49, 1027.22, 977.81, 973.49, 1033.44, 990.84, 1001.62, 1037.69, 1094.99, 1080.92, 996.04, 1022.71, 1020.55, 1030.52, 1007.0, 1164.35, 1009.12, 1006.74, 1051.39, 1067.41, 1113.18, 992.43, 1061.23, 1025.37, 1001.41, 1033.47, 1041.48, 966.98, 1019.44, 1072.97, 1009.67, 1030.47, 1067.38, 1029.74, 1006.73, 982.24, 1011.56, 1022.39, 1142.11, 1038.27, 1037.33, 1071.6, 1045.0, 1006.09, 1059.58, 983.65, 1044.65, 1021.93, 1035.56, 1059.95, 1048.74, 948.03, 966.19, 1021.4, 996.47, 1073.27, 1028.61, 1049.49, 1061.65] 14:55 - Checking status of HVPA channels in 61 drawer(s)... 14:55 - HV is locked in 0 channel(s), was in rise default in 0 channel(s) and was still in progress in 1 channel(s) 14:56 - Finished task "Set HV" 14:57 - ECC is in state EccState.Ready with status EccStatus.NoError 14:57 - ECC temperature sensors: T1= 26.4, T2= 25.9, T3= 27.3, T4= 28.2 deg C 14:57 - Back doors are closed. 14:57 - Light sensors: [0, 0, 0, 0] V 14:57 - Humidity: 0.0 %. Water pressure: [0.0, 0.0]. 14:57 - Fan speeds: [0.0, 0.0, 0.0, 0.0, 0.0, 0.0] rpm 14:57 - 24 V power supply no. 1 is enabled with a current of 61.800 A. 14:57 - Starting task "Check high voltages" 14:57 - Found 61 drawer(s) in Nominal state, 0 in Low state and 0 in Wait state 14:57 - Actual voltage is between 947.94 V and 1171.81 V. 14:57 - Low voltages range between 100.00 V and 100.00 V. 14:58 - Reference voltages range between 948.03 V and 1172.15 V. 14:58 - Maximum difference between expected and actual voltages is 1.10 V 14:58 - Maximum of current limits is 5647.07 uA 14:58 - Checking status of HVPA module in 61 drawer(s)... 14:58 - Checking status of HVPA channels in 61 drawer(s)... 14:58 - HV is stabilized in all channels. 14:58 - Checking reference and low voltages against /local/home/cta_test_bench/config/2019/20190312/NectarCAM.Run1113.NMC.xml 14:58 - Done 14:58 - Finished task "Check high voltages" 14:58 - High voltage locked channels will be checked every 30 s 14:58 - Stopping NMC 14:58 - Found 0 PPS errors. 14:58 - Starting NMC 14:58 - Clearing PPS error counters 14:58 - Configuring UCTS 14:58 - Configuring TIB... 14:58 - Setting TIB forced mode to False 14:58 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 14:58 - Status: TibState.PpsStopped 14:58 - Alarms: AlarmVector.NoAlarm 14:58 - Connection status: False 14:58 - Entering set_external_delay 14:58 - Setting ExternalDelayLocal to 0.000 ns 14:58 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelayLocal.ExternalDelayLocal_v 14:58 - Failed to write 'serveur.TIB.ExternalDelay.ExternalDelayLocal.ExternalDelayLocal_v': - overallStatus : Bad statuses are present - requestHandle : 7 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 14:58 - Writing 56.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 14:58 - Setting TIB trigger mode to 0x58 = TriggerMask.SlowControl|Software|SPhE 14:58 - Writing 88 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 14:58 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 14:58 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 14:58 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 14:58 - Writing False to serveur.TIB.Throttler.DisableThrottler.DisableThrottler_v 14:58 - Failed to write 'serveur.TIB.Throttler.DisableThrottler.DisableThrottler_v': - overallStatus : Bad statuses are present - requestHandle : 19 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 14:58 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 14:58 - Writing False to serveur.TIB.Throttler.DisableThrottlerWR.DisableThrottlerWR_v 14:58 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 14:58 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR50us.MaxTriggersWR50us_v 14:58 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 14:58 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR1ms.MaxTriggersWR1ms_v 14:58 - Status: TibState.PpsStopped 14:58 - Alarms: AlarmVector.NoAlarm 14:58 - Connection status: False 14:58 - Writing False to serveur.TIB.Pedestal.PeriodicPedestalEnable.PeriodicPedestalEnable_v 14:58 - Failed to write 'serveur.TIB.Pedestal.PeriodicPedestalEnable.PeriodicPedestalEnable_v': - overallStatus : Bad statuses are present - requestHandle : 35 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 14:58 - Connecting TIB to camera server at 10.10.4.12:222 14:58 - Starting TIB... 14:58 - Status: TibState.PpsStopped 14:58 - Alarms: AlarmVector.NoAlarm 14:58 - Connection status: True 14:58 - Resetting run 14:58 - Wait for UCTS external trigger before enabling trigger... 14:58 - Status: TibState.Standby 14:58 - Alarms: AlarmVector.NoAlarm 14:58 - Connection status: True 14:58 - Status: TibState.Standby 14:58 - Alarms: AlarmVector.NoAlarm 14:58 - Connection status: True 14:58 - Status: TibState.CoutingPps 14:58 - Alarms: AlarmVector.NoAlarm 14:58 - Connection status: True 14:59 - Starting TIB triggers... 14:59 - Enabling trigger 14:59 - Status: TibState.Running 14:59 - Alarms: AlarmVector.NoAlarm 14:59 - Connection status: True 14:59 - Checking for high voltage locked pixels... 14:59 - Configuring calibration box... 14:59 - Configuring calibration box with leds=0x40 voltage=10.00 frequency=1000.0/1 central_current=0.0 duration=400 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 14:59 - Starting flashes... 14:59 - Checking for high voltage locked pixels... 15:00 - Checking for high voltage locked pixels... 15:00 - Stopping TIB... 15:00 - Status: TibState.Running 15:00 - Alarms: AlarmVector.NoAlarm 15:00 - Connection status: True 15:00 - Disabling trigger 15:00 - Disabling PPS 15:00 - Status: TibState.PpsStopped 15:00 - Alarms: AlarmVector.NoAlarm 15:00 - Connection status: True 15:00 - Closing TIB connection to camera server 15:00 - Status: TibState.PpsStopped 15:00 - Alarms: AlarmVector.NoAlarm 15:00 - Connection status: False 15:00 - Run duration: 0:01:16 15:00 - Local camera triggers: 0 15:00 - Slow control triggers: 0 15:00 - Single photo-electron triggers: 39960 15:00 - Calibration triggers: 0 15:00 - Software triggers from UCTS: 0 15:00 - Pedestal triggers: 489276 15:00 - Collected input triggers: 39960 15:00 - Busy triggers: 0 15:00 - Camera event triggers sent to clusters: 39960