11:11 - Starting task "Check high voltages" 11:11 - Found 61 drawer(s) in Nominal state, 0 in Low state and 0 in Wait state 11:11 - Actual voltage is between 422.12 V and 1171.81 V. 11:11 - Low voltages range between 100.00 V and 100.00 V. 11:11 - Reference voltages range between 422.06 V and 1172.15 V. 11:12 - Maximum difference between expected and actual voltages is 0.71 V 11:12 - Maximum of current limits is 5647.07 uA 11:12 - Checking status of HVPA module in 61 drawer(s)... 11:12 - Checking status of HVPA channels in 61 drawer(s)... 11:12 - HV is stabilized in all channels. 11:12 - Checking reference and low voltages against /local/home/cta_test_bench/config/2019/20190312/NectarCAM.Run1112.NMC.xml 11:12 - Done 11:12 - Finished task "Check high voltages" 11:12 - Stopping NMC 11:12 - Found 0 PPS errors. 11:12 - Starting NMC 11:12 - Clearing PPS error counters 11:12 - High voltage locked channels will be checked every 30 s 11:12 - Resetting TIB... 11:12 - Configuring UCTS 11:12 - Configuring TIB... 11:12 - Setting TIB forced mode to False 11:12 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 11:12 - Status: TibState.RunStopped 11:12 - Alarms: AlarmVector.NoAlarm 11:12 - Connection status: False 11:12 - Disabling PPS 11:12 - Status: TibState.PpsStopped 11:12 - Alarms: AlarmVector.NoAlarm 11:12 - Connection status: False 11:12 - Entering set_external_delay 11:12 - Setting ExternalDelayLocal to 0.000 ns 11:12 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelayLocal.ExternalDelayLocal_v 11:12 - Failed to write 'serveur.TIB.ExternalDelay.ExternalDelayLocal.ExternalDelayLocal_v': - overallStatus : Bad statuses are present - requestHandle : 11 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 11:12 - Writing 56.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 11:12 - Setting TIB trigger mode to 0x58 = TriggerMask.SlowControl|Software|SPhE 11:12 - Writing 88 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 11:12 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 11:12 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 11:12 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 11:12 - Writing False to serveur.TIB.Throttler.DisableThrottler.DisableThrottler_v 11:12 - Failed to write 'serveur.TIB.Throttler.DisableThrottler.DisableThrottler_v': - overallStatus : Bad statuses are present - requestHandle : 23 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 11:12 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 11:12 - Writing False to serveur.TIB.Throttler.DisableThrottlerWR.DisableThrottlerWR_v 11:12 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 11:12 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR50us.MaxTriggersWR50us_v 11:12 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 11:12 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR1ms.MaxTriggersWR1ms_v 11:12 - Status: TibState.PpsStopped 11:12 - Alarms: AlarmVector.NoAlarm 11:12 - Connection status: False 11:12 - Writing False to serveur.TIB.Pedestal.PeriodicPedestalEnable.PeriodicPedestalEnable_v 11:12 - Failed to write 'serveur.TIB.Pedestal.PeriodicPedestalEnable.PeriodicPedestalEnable_v': - overallStatus : Bad statuses are present - requestHandle : 39 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 11:12 - Connecting TIB to camera server at 10.10.4.12:222 11:12 - Starting TIB... 11:12 - Status: TibState.PpsStopped 11:12 - Alarms: AlarmVector.NoAlarm 11:12 - Connection status: True 11:12 - Resetting run 11:12 - Wait for UCTS external trigger before enabling trigger... 11:12 - Status: TibState.Standby 11:12 - Alarms: AlarmVector.NoAlarm 11:12 - Connection status: True 11:12 - Status: TibState.Standby 11:12 - Alarms: AlarmVector.NoAlarm 11:12 - Connection status: True 11:12 - Status: TibState.CoutingPps 11:12 - Alarms: AlarmVector.NoAlarm 11:12 - Connection status: True 11:12 - Starting TIB triggers... 11:12 - Enabling trigger 11:12 - Status: TibState.Running 11:12 - Alarms: AlarmVector.NoAlarm 11:12 - Connection status: True 11:12 - Configuring calibration box... 11:12 - Configuring calibration box with leds=0x40 voltage=10.00 frequency=1000.0/1 central_current=0.0 duration=400 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 11:12 - Starting flashes... 11:13 - Checking for high voltage locked pixels... 11:13 - Checking for high voltage locked pixels... 11:13 - Stopping TIB... 11:13 - Status: TibState.Running 11:13 - Alarms: AlarmVector.NoAlarm 11:13 - Connection status: True 11:13 - Disabling trigger 11:13 - Disabling PPS 11:13 - Status: TibState.PpsStopped 11:13 - Alarms: AlarmVector.NoAlarm 11:13 - Connection status: True 11:13 - Closing TIB connection to camera server 11:13 - Status: TibState.PpsStopped 11:13 - Alarms: AlarmVector.NoAlarm 11:13 - Connection status: False 11:13 - Run duration: 0:01:01 11:13 - Local camera triggers: 0 11:13 - Slow control triggers: 0 11:13 - Single photo-electron triggers: 39903 11:13 - Calibration triggers: 0 11:13 - Software triggers from UCTS: 0 11:13 - Pedestal triggers: 390970 11:13 - Collected input triggers: 39903 11:13 - Busy triggers: 0 11:13 - Camera event triggers sent to clusters: 39903 11:13 - Stopped periodic check of locked high voltages 11:13 - Stopping NMC 11:14 - Found 0 PPS errors.