17:42 - Successfully configured 61 module(s) 17:42 - Checking for high voltage locked pixels... 17:42 - NMC is in state NmcState.Configured and knows of 61 drawer(s) 17:42 - Found 0 PPS errors. 17:42 - Finished task "Configure modules" 17:42 - Starting task "Switch HVPA voltage state" 17:42 - Setting HVPA current limit to 12489.75 uA 17:42 - Checking for high voltage locked pixels... 17:42 - Stopped periodic check of locked high voltages 17:42 - Setting HVPA ramp speed to 35 V/s 17:42 - Switching HVPA to state Nominal 17:43 - Setting HVPA current limits... 17:43 - Finished task "Switch HVPA voltage state" 17:43 - Resetting NMC 17:43 - Starting task "Configure modules" 17:43 - Configuring modules with configuration /local/home/cta_test_bench/config/2019/20190308/config_61modules_run1104.NMC.xml 17:43 - Successfully configured 61 module(s) 17:43 - NMC is in state NmcState.Configured and knows of 61 drawer(s) 17:43 - Found 0 PPS errors. 17:43 - Finished task "Configure modules" 17:43 - Starting task "Switch HVPA voltage state" 17:43 - Setting HVPA current limit to 12489.75 uA 17:44 - Setting HVPA ramp speed to 35 V/s 17:44 - Switching HVPA to state Nominal 17:44 - Setting HVPA current limits... 17:44 - ECC is in state EccState.Ready with status EccStatus.NoError 17:44 - ECC temperature sensors: T1= 26.0, T2= 25.5, T3= 26.8, T4= 27.7 deg C 17:44 - Back doors are closed. 17:44 - Light sensors: [0, 0, 0, 0] V 17:44 - Humidity: 0.0 %. Water pressure: [0.0, 0.0]. 17:44 - Fan speeds: [0.0, 0.0, 0.0, 0.0, 0.0, 0.0] rpm 17:44 - 24 V power supply no. 1 is enabled with a current of 60.800 A. 17:44 - Finished task "Switch HVPA voltage state" 17:44 - Starting task "Check high voltages" 17:44 - Found 61 drawer(s) in Nominal state, 0 in Low state and 0 in Wait state 17:44 - Actual voltage is between 143.96 V and 1173.03 V. 17:44 - Low voltages range between 100.00 V and 100.00 V. 17:45 - Reference voltages range between 948.03 V and 1172.93 V. 17:45 - Maximum difference between expected and actual voltages is 926.46 V 17:45 - Maximum of current limits is 5647.07 uA 17:45 - Checking status of HVPA module in 61 drawer(s)... 17:45 - HVPA module in drawer 113 has a status of 0x3f! 17:45 - HVPA module in drawer 115 has a status of 0x7b! 17:45 - HVPA module in drawer 116 has a status of 0x5d! 17:45 - HVPA module in drawer 118 has a status of 0x6f! 17:45 - HVPA module in drawer 127 has a status of 0x7b! 17:45 - HVPA module in drawer 131 has a status of 0x67! 17:45 - HVPA module in drawer 147 has a status of 0x1f! 17:45 - HVPA module in drawer 149 has a status of 0x4f! 17:45 - HVPA module in drawer 153 has a status of 0x7e! 17:45 - HVPA module in drawer 163 has a status of 0x77! 17:45 - HVPA module in drawer 164 has a status of 0x6b! 17:45 - HVPA module in drawer 166 has a status of 0x5f! 17:45 - HVPA module in drawer 167 has a status of 0x77! 17:45 - Checking status of HVPA channels in 61 drawer(s)... 17:45 - HVPA channel 0 of drawer 153 has status 0x8003! 17:45 - HVPA channel 1 of drawer 116 has status 0x8003! 17:45 - HVPA channel 2 of drawer 115 has status 0x8003! 17:45 - HVPA channel 2 of drawer 127 has status 0x8003! 17:45 - HVPA channel 2 of drawer 164 has status 0x8007! 17:45 - HVPA channel 3 of drawer 131 has status 0x8003! 17:45 - HVPA channel 3 of drawer 163 has status 0x8003! 17:45 - HVPA channel 3 of drawer 167 has status 0x8007! 17:45 - HVPA channel 4 of drawer 118 has status 0x8003! 17:45 - HVPA channel 4 of drawer 131 has status 0x8003! 17:45 - HVPA channel 4 of drawer 149 has status 0x8003! 17:45 - HVPA channel 4 of drawer 164 has status 0x8007! 17:45 - HVPA channel 5 of drawer 116 has status 0x8003! 17:45 - HVPA channel 5 of drawer 147 has status 0x8003! 17:45 - HVPA channel 5 of drawer 149 has status 0x8003! 17:45 - HVPA channel 5 of drawer 166 has status 0x8007! 17:45 - HVPA channel 6 of drawer 113 has status 0x8003! 17:45 - HVPA channel 6 of drawer 147 has status 0x8003! 17:45 - HV is locked in 18 channel(s), was in rise default in 0 channel(s) and was still in progress in 0 channel(s) 17:45 - Resetting 18 channel(s)... 17:45 - Resetting HVPA channel 0 of drawer 153... 17:45 - Resetting HVPA channel 1 of drawer 116... 17:45 - Resetting HVPA channel 2 of drawer 115... 17:45 - Resetting HVPA channel 2 of drawer 127... 17:45 - Resetting HVPA channel 2 of drawer 164... 17:45 - Resetting HVPA channel 3 of drawer 131... 17:45 - Resetting HVPA channel 3 of drawer 163... 17:45 - Resetting HVPA channel 3 of drawer 167... 17:45 - Resetting HVPA channel 4 of drawer 118... 17:45 - Resetting HVPA channel 4 of drawer 131... 17:45 - Resetting HVPA channel 4 of drawer 149... 17:45 - Resetting HVPA channel 4 of drawer 164... 17:45 - Resetting HVPA channel 5 of drawer 116... 17:45 - Resetting HVPA channel 5 of drawer 147... 17:45 - Resetting HVPA channel 5 of drawer 149... 17:45 - Resetting HVPA channel 5 of drawer 166... 17:45 - Resetting HVPA channel 6 of drawer 113... 17:45 - Resetting HVPA channel 6 of drawer 147... 17:45 - Checking reference and low voltages against /local/home/cta_test_bench/config/2019/20190308/config_61modules_run1104.NMC.xml 17:45 - Reference voltage of channel 5 in drawer #149: expected 1020.07, read 0.00 17:45 - Done 17:45 - Finished task "Check high voltages" 17:45 - Starting task "Check high voltages" 17:45 - Found 61 drawer(s) in Nominal state, 0 in Low state and 0 in Wait state 17:46 - Actual voltage is between 120.17 V and 1173.03 V. 17:46 - Low voltages range between 100.00 V and 100.00 V. 17:46 - Reference voltages range between 0.00 V and 1172.93 V. 17:46 - Maximum difference between expected and actual voltages is 109.80 V 17:46 - Maximum of current limits is 5647.07 uA 17:46 - Checking status of HVPA module in 61 drawer(s)... 17:46 - HVPA module in drawer 149 has a status of 0x5f! 17:46 - Checking status of HVPA channels in 61 drawer(s)... 17:46 - HVPA channel 5 of drawer 149 has status 0x8003! 17:46 - HV is locked in 1 channel(s), was in rise default in 0 channel(s) and was still in progress in 0 channel(s) 17:46 - Resetting 1 channel(s)... 17:46 - Resetting HVPA channel 5 of drawer 149... 17:46 - Checking reference and low voltages against /local/home/cta_test_bench/config/2019/20190308/config_61modules_run1104.NMC.xml 17:46 - Done 17:46 - Finished task "Check high voltages" 17:46 - Starting task "Check high voltages" 17:46 - Found 61 drawer(s) in Nominal state, 0 in Low state and 0 in Wait state 17:47 - Actual voltage is between 804.59 V and 1173.03 V. 17:47 - Low voltages range between 100.00 V and 100.00 V. 17:47 - Reference voltages range between 948.03 V and 1172.93 V. 17:47 - Maximum difference between expected and actual voltages is 0.89 V 17:47 - Maximum of current limits is 5647.07 uA 17:47 - Checking status of HVPA module in 61 drawer(s)... 17:47 - Checking status of HVPA channels in 61 drawer(s)... 17:47 - HV is stabilized in all channels. 17:47 - Checking reference and low voltages against /local/home/cta_test_bench/config/2019/20190308/config_61modules_run1104.NMC.xml 17:47 - Done 17:47 - Finished task "Check high voltages" 17:47 - High voltage locked channels will be checked every 30 s 17:47 - Starting NMC 17:47 - Clearing PPS error counters 17:48 - Configuring UCTS 17:48 - Configuring TIB... 17:48 - Setting TIB forced mode to False 17:48 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 17:48 - Status: TibState.PpsStopped 17:48 - Alarms: AlarmVector.NoAlarm 17:48 - Connection status: False 17:48 - Entering set_external_delay 17:48 - Setting ExternalDelayLocal to 0.000 ns 17:48 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelayLocal.ExternalDelayLocal_v 17:48 - Failed to write 'serveur.TIB.ExternalDelay.ExternalDelayLocal.ExternalDelayLocal_v': - overallStatus : Bad statuses are present - requestHandle : 7 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 17:48 - Writing 56.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 17:48 - Setting TIB trigger mode to 0x58 = TriggerMask.SlowControl|Software|SPhE 17:48 - Writing 88 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 17:48 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 17:48 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 17:48 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 17:48 - Writing False to serveur.TIB.Throttler.DisableThrottler.DisableThrottler_v 17:48 - Failed to write 'serveur.TIB.Throttler.DisableThrottler.DisableThrottler_v': - overallStatus : Bad statuses are present - requestHandle : 19 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 17:48 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 17:48 - Writing False to serveur.TIB.Throttler.DisableThrottlerWR.DisableThrottlerWR_v 17:48 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 17:48 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR50us.MaxTriggersWR50us_v 17:48 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 17:48 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR1ms.MaxTriggersWR1ms_v 17:48 - Status: TibState.PpsStopped 17:48 - Alarms: AlarmVector.NoAlarm 17:48 - Connection status: False 17:48 - Writing False to serveur.TIB.Pedestal.PeriodicPedestalEnable.PeriodicPedestalEnable_v 17:48 - Failed to write 'serveur.TIB.Pedestal.PeriodicPedestalEnable.PeriodicPedestalEnable_v': - overallStatus : Bad statuses are present - requestHandle : 35 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 17:48 - Connecting TIB to camera server at 10.10.4.12:222 17:48 - Starting TIB... 17:48 - Status: TibState.PpsStopped 17:48 - Alarms: AlarmVector.NoAlarm 17:48 - Connection status: True 17:48 - Resetting run 17:48 - Wait for UCTS external trigger before enabling trigger... 17:48 - Status: TibState.Standby 17:48 - Alarms: AlarmVector.NoAlarm 17:48 - Connection status: True 17:48 - Status: TibState.Standby 17:48 - Alarms: AlarmVector.NoAlarm 17:48 - Connection status: True 17:48 - Status: TibState.CoutingPps 17:48 - Alarms: AlarmVector.NoAlarm 17:48 - Connection status: True 17:48 - Starting TIB triggers... 17:48 - Enabling trigger 17:48 - Status: TibState.Running 17:48 - Alarms: AlarmVector.NoAlarm 17:48 - Connection status: True 17:48 - Checking for high voltage locked pixels... 17:48 - Checking for high voltage locked pixels... 17:49 - Checking for high voltage locked pixels... 17:49 - Checking for high voltage locked pixels... 17:49 - Configuring calibration box... 17:49 - Configuring calibration box with leds=0x40 voltage=10.00 frequency=1000.0/1 central_current=0.0 duration=400 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 17:49 - Starting flashes... 17:50 - Checking for high voltage locked pixels... 17:50 - Stopping TIB... 17:50 - Status: TibState.Running 17:50 - Alarms: AlarmVector.NoAlarm 17:50 - Connection status: True 17:50 - Disabling trigger 17:50 - Disabling PPS 17:50 - Status: TibState.PpsStopped 17:50 - Alarms: AlarmVector.NoAlarm 17:50 - Connection status: True 17:50 - Closing TIB connection to camera server 17:50 - Checking for high voltage locked pixels... 17:50 - Status: TibState.PpsStopped 17:50 - Alarms: AlarmVector.NoAlarm 17:50 - Connection status: False 17:50 - Run duration: 0:02:43 17:50 - Local camera triggers: 0 17:50 - Slow control triggers: 0 17:50 - Single photo-electron triggers: 39901 17:50 - Calibration triggers: 0 17:50 - Software triggers from UCTS: 0 17:50 - Pedestal triggers: 1059033 17:50 - Collected input triggers: 39901 17:50 - Busy triggers: 0 17:50 - Camera event triggers sent to clusters: 39901 17:51 - Stopping NMC 17:51 - Found 0 PPS errors.