13:16 - ECC is in state EccState.Ready with status EccStatus.NoError 13:16 - ECC temperature sensors: T1= 24.9, T2= 24.4, T3= 25.6, T4= 26.6 deg C 13:16 - Back doors are closed. 13:16 - Light sensors: [0, 0, 0, 0] V 13:16 - Humidity: 0.0 %. Water pressure: [0.0, 0.0]. 13:16 - Fan speeds: [0.0, 0.0, 0.0, 0.0, 0.0, 0.0] rpm 13:16 - 24 V power supply no. 1 is enabled with a current of 61.700 A. 13:16 - Starting task "Check high voltages" 13:16 - Found 61 drawer(s) in Nominal state, 0 in Low state and 0 in Wait state 13:16 - Actual voltage is between 963.80 V and 1222.44 V. 13:16 - Low voltages range between 100.00 V and 100.00 V. 13:16 - Reference voltages range between 963.80 V and 1223.01 V. 13:16 - Maximum difference between expected and actual voltages is 1.01 V 13:16 - Maximum of current limits is 5647.07 uA 13:16 - Checking status of HVPA module in 61 drawer(s)... 13:16 - Checking status of HVPA channels in 61 drawer(s)... 13:17 - HV is stabilized in all channels. 13:17 - Checking reference and low voltages against /local/home/cta_test_bench/config/2019/20190306/config_61modules_newfebs_Ibof_Dacl_+20V.NMC.xml 13:17 - Done 13:17 - Finished task "Check high voltages" 13:18 - High voltage locked channels will be checked every 30 s 13:18 - Starting NMC 13:18 - Clearing PPS error counters 13:18 - ("NmcError: Failed to call 'NectarFrontEnd_113.Dtbp.readRegister': status Bad statuses are present, code 0xfffffffe, status NmcStatus.Timeout", 4294967294) 13:18 - Stopping NMC 13:18 - Found 0 PPS errors. 13:18 - Starting NMC 13:18 - Clearing PPS error counters 13:18 - Configuring UCTS 13:18 - Configuring TIB... 13:18 - Setting TIB forced mode to False 13:18 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 13:18 - Status: TibState.PpsStopped 13:18 - Alarms: AlarmVector.NoAlarm 13:18 - Connection status: False 13:18 - Entering set_external_delay 13:18 - Setting ExternalDelayLocal to 0.000 ns 13:18 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelayLocal.ExternalDelayLocal_v 13:18 - Failed to write 'serveur.TIB.ExternalDelay.ExternalDelayLocal.ExternalDelayLocal_v': - overallStatus : Bad statuses are present - requestHandle : 7 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 13:18 - Writing 56.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 13:18 - Setting TIB trigger mode to 0x58 = TriggerMask.SlowControl|Software|SPhE 13:18 - Writing 88 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 13:18 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 13:18 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 13:18 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 13:18 - Writing False to serveur.TIB.Throttler.DisableThrottler.DisableThrottler_v 13:18 - Failed to write 'serveur.TIB.Throttler.DisableThrottler.DisableThrottler_v': - overallStatus : Bad statuses are present - requestHandle : 19 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 13:18 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 13:18 - Writing False to serveur.TIB.Throttler.DisableThrottlerWR.DisableThrottlerWR_v 13:18 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 13:18 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR50us.MaxTriggersWR50us_v 13:18 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 13:18 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR1ms.MaxTriggersWR1ms_v 13:18 - Status: TibState.PpsStopped 13:18 - Alarms: AlarmVector.NoAlarm 13:18 - Connection status: False 13:18 - Writing False to serveur.TIB.Pedestal.PeriodicPedestalEnable.PeriodicPedestalEnable_v 13:18 - Failed to write 'serveur.TIB.Pedestal.PeriodicPedestalEnable.PeriodicPedestalEnable_v': - overallStatus : Bad statuses are present - requestHandle : 35 - targets[] - targets[0] status: The server could not successfully process the Write service: BadNodeIdUnknown: The server could not successfully process the Write service: BadNodeIdUnknown - opcUaStatusCode : 2.15089e+09 13:18 - Checking for high voltage locked pixels... 13:18 - Connecting TIB to camera server at 10.10.4.12:222 13:18 - Starting TIB... 13:18 - Status: TibState.PpsStopped 13:18 - Alarms: AlarmVector.NoAlarm 13:18 - Connection status: True 13:18 - Resetting run 13:18 - Wait for UCTS external trigger before enabling trigger... 13:18 - Status: TibState.Standby 13:18 - Alarms: AlarmVector.NoAlarm 13:18 - Connection status: True 13:18 - Status: TibState.Standby 13:18 - Alarms: AlarmVector.NoAlarm 13:18 - Connection status: True 13:18 - Status: TibState.CoutingPps 13:18 - Alarms: AlarmVector.NoAlarm 13:18 - Connection status: True 13:18 - Starting TIB triggers... 13:18 - Enabling trigger 13:18 - Status: TibState.Running 13:18 - Alarms: AlarmVector.NoAlarm 13:18 - Connection status: True 13:19 - Configuring calibration box... 13:19 - Configuring calibration box with leds=0x40 voltage=10.00 frequency=1000.0/1 central_current=0.0 duration=400 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 13:19 - Starting flashes... 13:19 - Checking for high voltage locked pixels... 13:19 - Checking for high voltage locked pixels... 13:19 - Stopping TIB... 13:19 - Status: TibState.Running 13:19 - Alarms: AlarmVector.NoAlarm 13:19 - Connection status: True 13:19 - Disabling trigger 13:19 - Disabling PPS 13:19 - Status: TibState.PpsStopped 13:20 - Alarms: AlarmVector.NoAlarm 13:20 - Connection status: True 13:20 - Closing TIB connection to camera server 13:20 - Status: TibState.PpsStopped 13:20 - Alarms: AlarmVector.NoAlarm 13:20 - Connection status: False 13:20 - Run duration: 0:01:03 13:20 - Local camera triggers: 0 13:20 - Slow control triggers: 0 13:20 - Single photo-electron triggers: 39920 13:20 - Calibration triggers: 0 13:20 - Software triggers from UCTS: 0 13:20 - Pedestal triggers: 409711 13:20 - Collected input triggers: 39920 13:20 - Busy triggers: 0 13:20 - Camera event triggers sent to clusters: 39920 13:20 - Stopping NMC 13:20 - Found 0 PPS errors. 13:20 - Stopped periodic check of locked high voltages