13:53 - ECC is in state EccState.Ready with status EccStatus.NoError 13:53 - ECC temperature sensors: T1= 26.7, T2= 26.3, T3= 27.5, T4= 28.3 deg C 13:53 - 24 V power supply no. 1 is enabled with a current of 62.500 A. 13:53 - Starting task "Set HV" 13:53 - Checking status of HVPA channels in 6 drawer(s)... 13:53 - HV is stabilized in all channels. 13:53 - Setting HV to nominal values... 13:53 - Setting channel 0 voltages to [1033.05, 1031.0, 1007.0, 1031.94, 971.0, 990.0] 13:53 - Setting channel 1 voltages to [1041.73, 1101.0, 1072.0, 1009.21, 1012.08, 966.0] 13:53 - Setting channel 2 voltages to [1024.86, 1004.73, 1068.91, 1074.26, 1036.0, 999.0] 13:53 - Setting channel 3 voltages to [1091.0, 1056.27, 986.79, 1048.0, 1124.72, 1086.22] 13:53 - Setting channel 4 voltages to [1018.11, 1125.04, 993.06, 1047.0, 1039.12, 1060.0] 13:53 - Setting channel 5 voltages to [1059.85, 1028.84, 1043.99, 1012.0, 1057.0, 1007.0] 13:53 - Setting channel 6 voltages to [1000.11, 1036.0, 1050.0, 1028.25, 1057.0, 1045.0] 13:53 - Checking status of HVPA channels in 6 drawer(s)... 13:53 - HV is locked in 0 channel(s), was in rise default in 0 channel(s) and was still in progress in 35 channel(s) 13:53 - Finished task "Set HV" 13:54 - Starting task "Check high voltages" 13:54 - Checking reference and low voltages against /local/home/cta_test_bench/config/2019/20190111/NectarCAM.Run1056+12V.NMC.xml 13:54 - Done 13:54 - Found 6 drawer(s) in Nominal state, 0 in Low state and 0 in Wait state 13:54 - Low voltages range between 100.00 V and 100.00 V. 13:54 - Reference voltages range between 966.00 V and 1125.04 V. 13:54 - Actual voltage is between 965.63 V and 1124.84 V. 13:54 - Maximum difference between expected and actual voltages is 0.63 V 13:54 - Maximum of current limits is 4925.14 uA 13:54 - Checking status of HVPA module in 6 drawer(s)... 13:54 - Checking status of HVPA channels in 6 drawer(s)... 13:54 - HV is stabilized in all channels. 13:54 - Finished task "Check high voltages" 13:54 - Stopping NMC 13:54 - Found 0 PPS errors. 13:54 - Starting NMC 13:54 - Clearing PPS error counters 13:54 - Configuring UCTS 13:54 - Configuring TIB... 13:54 - Setting TIB forced mode to False 13:54 - Writing False to Camera.TIB.Forced.ForcedMode.ForcedMode_v 13:54 - Status: TibState.PpsStopped 13:54 - Alarms: AlarmVector.ReadError 13:54 - Connection status: False 13:54 - Entering set_external_delay 13:54 - Setting ExternalDelayLocal to 0.000 ns 13:54 - Writing 0.0 to Camera.TIB.ExternalDelay.ExternalDelayLocal.ExternalDelayLocal_v 13:54 - Entering set_external_delay 13:54 - Setting ExternalDelayCalibration to 76.000 ns 13:54 - Writing 76.0 to Camera.TIB.ExternalDelay.ExternalDelayCalibration.ExternalDelayCalibration_v 13:54 - Entering set_external_delay 13:54 - Setting ExternalDelaySphe to 0.000 ns 13:54 - Writing 0.0 to Camera.TIB.ExternalDelay.ExternalDelaySphe.ExternalDelaySphe_v 13:54 - Setting TIB trigger mode to 0x44 = TriggerMask.SlowControl|Calibration 13:54 - Writing 68 to Camera.TIB.TriggerMode.ModeMask.ModeMask_v 13:54 - Writing 0 to Camera.TIB.InputsEnable.InputMask.InputMask_v 13:54 - Writing False to Camera.TIB.BUSY.DisableBusy.DisableBusy_v 13:54 - Writing 0.0 to Camera.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 13:54 - Writing False to Camera.TIB.Throttler.DisableThrottler.DisableThrottler_v 13:54 - Writing 255 to Camera.TIB.Throttler.MaxTriggers50us.MaxTriggers50us_v 13:54 - Writing 255 to Camera.TIB.Throttler.MaxTriggers1ms.MaxTriggers1ms_v 13:54 - Status: TibState.PpsStopped 13:54 - Alarms: AlarmVector.ReadError 13:54 - Connection status: False 13:54 - Writing False to Camera.TIB.Pedestal.PeriodicPedestalEnable.PeriodicPedestalEnable_v 13:54 - Writing 1000 to Camera.TIB.Pedestal.PeriodicPedestalFrequency.PeriodicPedestalFrequency_v 13:54 - Writing False to Camera.TIB.Pedestal.Fake_trig_enable.Fake_trig_enable_v 13:54 - Writing False to Camera.TIB.Pedestal.DigitalPedestalEnable.DigitalPedestalEnable_v 13:54 - Writing 1000 to Camera.TIB.Pedestal.DigitalPedestal_config_Rate.DigitalPedestal_config_Rate_v 13:54 - Writing 375764 to Camera.TIB.Pedestal.DigitalPedestalSeed.DigitalPedestalSeed_v 13:54 - Writing False to Camera.TIB.Pedestal.Fake_trig_enable.Fake_trig_enable_v 13:54 - Writing False to Camera.TIB.Pedestal.AnalogPedestalEnable.AnalogPedestalEnable_v 13:54 - Writing 3000.0 to Camera.TIB.Pedestal.AnalogPedestalThreshold.AnalogPedestalThreshold_v 13:54 - Writing False to Camera.TIB.Pedestal.Fake_trig_enable.Fake_trig_enable_v 13:54 - Connecting TIB to camera server at 10.10.4.12:222 13:54 - Starting TIB... 13:54 - Status: TibState.PpsStopped 13:54 - Alarms: AlarmVector.ReadError 13:54 - Connection status: False 13:54 - Resetting run 13:54 - Wait for UCTS external trigger before enabling trigger... 13:54 - Status: TibState.Standby 13:54 - Alarms: AlarmVector.NoAlarm 13:54 - Connection status: False 13:54 - Status: TibState.Standby 13:54 - Alarms: AlarmVector.NoAlarm 13:54 - Connection status: False 13:54 - Status: TibState.Armed 13:54 - Alarms: AlarmVector.NoAlarm 13:54 - Connection status: True 13:54 - Starting TIB triggers... 13:54 - Enabling trigger 13:54 - Status: TibState.Running 13:54 - Alarms: AlarmVector.NoAlarm 13:54 - Connection status: True 13:54 - Configuring calibration box... 13:54 - Configuring calibration box with leds=0x40 voltage=10.00 frequency=1000.0/1 central_current=0.0 duration=300 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 13:54 - Starting flashes... 13:55 - Stopping TIB... 13:55 - Status: TibState.Running 13:55 - Alarms: AlarmVector.ReadError 13:55 - Connection status: True 13:55 - Disabling trigger 13:55 - Disabling PPS 13:55 - Status: TibState.PpsStopped 13:55 - Alarms: AlarmVector.ReadError 13:55 - Connection status: True 13:55 - Closing TIB connection to camera server 13:55 - Status: TibState.PpsStopped 13:55 - Alarms: AlarmVector.ReadError 13:55 - Connection status: False 13:55 - Run duration: 0:00:41 13:55 - Local camera triggers: 0 13:55 - Slow control triggers: 0 13:55 - Single photo-electron triggers: 0 13:55 - Calibration triggers: 29942 13:55 - Software triggers from UCTS: 0 13:55 - Pedestal triggers: 0 13:55 - Collected input triggers: 29942 13:55 - Busy triggers: 0 13:55 - Camera event triggers sent to clusters: 29942 13:55 - Stopping NMC 13:55 - Found 0 PPS errors. 13:55 - Starting task "Check high voltages" 13:55 - Checking reference and low voltages against /local/home/cta_test_bench/config/2019/20190111/NectarCAM.Run1056+12V.NMC.xml 13:55 - Done 13:55 - Found 6 drawer(s) in Nominal state, 0 in Low state and 0 in Wait state 13:55 - Low voltages range between 100.00 V and 100.00 V. 13:55 - Reference voltages range between 966.00 V and 1125.04 V. 13:55 - Actual voltage is between 965.63 V and 1124.84 V. 13:55 - Maximum difference between expected and actual voltages is 0.59 V 13:55 - Maximum of current limits is 4925.14 uA 13:55 - Checking status of HVPA module in 6 drawer(s)... 13:55 - Checking status of HVPA channels in 6 drawer(s)... 13:55 - HV is stabilized in all channels. 13:55 - Finished task "Check high voltages"