10:36 - ECC is in state EccState.Ready with status EccStatus.NoError 10:36 - ECC temperature sensors: T1= 25.2, T2= 24.4, T3= 25.9, T4= 26.8 deg C 10:36 - 24 V power supply no. 1 is enabled with a current of 39.900 A. 10:36 - NMC is in state NmcState.Running and knows of 37 drawer(s) 10:36 - Found 0 PPS errors. 10:36 - Stopping NMC 10:36 - Found 0 PPS errors. 10:36 - Checking high voltages... 10:36 - Starting task "Check HV" 10:36 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20181204/config_37modules_Ibof_Dacl2_1050V.NMC.xml 10:37 - Done 10:37 - Found 37 drawer(s) in Nominal state, 0 in Low state and 0 in Wait state 10:37 - Found 37 drawer(s). Reference voltage is between 1050.00 V and 1050.00 V. Actual voltage is between 1049.20 V and 1050.42 V. 10:37 - Maximum difference between expected and actual voltages in drawer 76 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 77 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 78 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 79 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 80 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 81 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 93 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 94 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 95 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 96 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 97 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 98 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 110 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 111 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 112 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 113 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 114 is 1.03 V 10:37 - Maximum difference between expected and actual voltages in drawer 115 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 116 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 128 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 129 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 130 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 131 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 132 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 133 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 145 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 146 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 147 is 1.03 V 10:37 - Maximum difference between expected and actual voltages in drawer 148 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 149 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 150 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 163 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 164 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 165 is 1.03 V 10:37 - Maximum difference between expected and actual voltages in drawer 166 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 167 is 0.42 V 10:37 - Maximum difference between expected and actual voltages in drawer 168 is 0.42 V 10:37 - Checking status of HVPA module in 37 drawer(s)... 10:37 - Checking status of HVPA channels in 37 drawer(s)... 10:37 - HV is stabilized in all channels. 10:37 - Finished task "Check HV" 10:37 - Starting NMC 10:37 - Clearing PPS error counters 10:37 - Configuring TIB... 10:37 - Setting TIB forced mode to False 10:37 - Writing False to Camera.TIB.Forced.ForcedMode.ForcedMode_v 10:37 - Status: TibState.PpsStopped 10:37 - Alarms: AlarmVector.ReadError 10:37 - Connection status: False 10:37 - Entering set_external_delay 10:37 - Setting ExternalDelayLocal to 0.000 ns 10:37 - Writing 0.0 to Camera.TIB.ExternalDelay.ExternalDelayLocal.ExternalDelayLocal_v 10:37 - Entering set_external_delay 10:37 - Setting ExternalDelayCalibration to 76.000 ns 10:37 - Writing 76.0 to Camera.TIB.ExternalDelay.ExternalDelayCalibration.ExternalDelayCalibration_v 10:37 - Entering set_external_delay 10:37 - Setting ExternalDelaySphe to 0.000 ns 10:37 - Writing 0.0 to Camera.TIB.ExternalDelay.ExternalDelaySphe.ExternalDelaySphe_v 10:37 - Setting TIB trigger mode to 0x44 = TriggerMask.SlowControl|Calibration 10:37 - Writing 68 to Camera.TIB.TriggerMode.ModeMask.ModeMask_v 10:37 - Writing 0 to Camera.TIB.InputsEnable.InputMask.InputMask_v 10:37 - Writing False to Camera.TIB.BUSY.DisableBusy.DisableBusy_v 10:37 - Writing 0.0 to Camera.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 10:37 - Writing False to Camera.TIB.Throttler.DisableThrottler.DisableThrottler_v 10:37 - Writing 255 to Camera.TIB.Throttler.MaxTriggers50us.MaxTriggers50us_v 10:37 - Writing 255 to Camera.TIB.Throttler.MaxTriggers1ms.MaxTriggers1ms_v 10:37 - Status: TibState.PpsStopped 10:37 - Alarms: AlarmVector.ReadError 10:37 - Connection status: False 10:37 - Writing False to Camera.TIB.Pedestal.PeriodicPedestalEnable.PeriodicPedestalEnable_v 10:37 - Writing 1000 to Camera.TIB.Pedestal.PeriodicPedestalFrequency.PeriodicPedestalFrequency_v 10:37 - Writing False to Camera.TIB.Pedestal.Fake_trig_enable.Fake_trig_enable_v 10:37 - Writing False to Camera.TIB.Pedestal.DigitalPedestalEnable.DigitalPedestalEnable_v 10:37 - Writing 1000 to Camera.TIB.Pedestal.DigitalPedestal_config_Rate.DigitalPedestal_config_Rate_v 10:37 - Writing 375764 to Camera.TIB.Pedestal.DigitalPedestalSeed.DigitalPedestalSeed_v 10:37 - Writing False to Camera.TIB.Pedestal.Fake_trig_enable.Fake_trig_enable_v 10:37 - Writing False to Camera.TIB.Pedestal.AnalogPedestalEnable.AnalogPedestalEnable_v 10:37 - Writing 3000.0 to Camera.TIB.Pedestal.AnalogPedestalThreshold.AnalogPedestalThreshold_v 10:37 - Writing False to Camera.TIB.Pedestal.Fake_trig_enable.Fake_trig_enable_v 10:37 - Connecting TIB to camera server at 10.10.4.12:222 10:37 - Starting TIB... 10:37 - Status: TibState.PpsStopped 10:37 - Alarms: AlarmVector.ReadError 10:37 - Connection status: False 10:37 - Resetting run 10:37 - Wait for UCTS external trigger before enabling trigger... 10:37 - Status: TibState.Standby 10:37 - Alarms: AlarmVector.NoAlarm 10:37 - Connection status: False 10:37 - Status: TibState.Standby 10:37 - Alarms: AlarmVector.NoAlarm 10:37 - Connection status: False 10:37 - Status: TibState.Armed 10:37 - Alarms: AlarmVector.NoAlarm 10:37 - Connection status: True 10:37 - Starting TIB triggers... 10:37 - Enabling trigger 10:37 - Status: TibState.Running 10:37 - Alarms: AlarmVector.NoAlarm 10:37 - Connection status: True 10:37 - Configuring calibration box... 10:37 - Configuring calibration box with leds=0x40 voltage=12.00 frequency=1000.0/1 central_current=0.0 duration=300 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 10:37 - Starting flashes... 10:38 - Stopping TIB... 10:38 - Status: TibState.Running 10:38 - Alarms: AlarmVector.ReadError 10:38 - Connection status: True 10:38 - Disabling trigger 10:38 - Disabling PPS 10:38 - Status: TibState.PpsStopped 10:38 - Alarms: AlarmVector.ReadError 10:38 - Connection status: True 10:38 - Closing TIB connection to camera server 10:38 - Status: TibState.PpsStopped 10:38 - Alarms: AlarmVector.ReadError 10:38 - Connection status: False 10:38 - Run duration: 0:00:59 10:38 - Local camera triggers: 0 10:38 - Slow control triggers: 0 10:38 - Single photo-electron triggers: 0 10:38 - Calibration triggers: 29920 10:38 - Software triggers from UCTS: 0 10:38 - Pedestal triggers: 0 10:38 - Collected input triggers: 29920 10:38 - Busy triggers: 0 10:38 - Camera event triggers sent to clusters: 29920