16:15 - Starting task "Configure NMC" 16:15 - Configuring modules with configuration /local/home/cta_test_bench/tests/2018/20180621/NectarCAM.Run0861.NMC.xml 16:15 - NMC is in state NmcState.Configured and knows of 6 drawer(s) 16:15 - Found 0 PPS errors. 16:15 - Finished task "Configure NMC" 16:15 - Checking high voltages... 16:15 - Starting task "Check HV" 16:15 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180621/NectarCAM.Run0861.NMC.xml 16:15 - Done 16:15 - Found 6 drawer(s). Reference voltage is between 959.43 V and 1289.01 V. Actual voltage is between 951.60 V and 984.54 V. 16:15 - Maximum difference between reference and actual voltage is 293.49 V 16:15 - Checking status of HVPA module in 6 drawer(s)... 16:15 - Checking status of HVPA channels in 6 drawer(s)... 16:15 - HV was locked in 0 channel(s), was in rise default in 0 channel(s) and was still in progress in 35 channel(s) 16:15 - Finished task "Check HV" 16:16 - Checking high voltages... 16:16 - Starting task "Check HV" 16:16 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180621/NectarCAM.Run0861.NMC.xml 16:16 - Done 16:16 - Found 6 drawer(s). Reference voltage is between 959.43 V and 1289.01 V. Actual voltage is between 960.14 V and 1289.54 V. 16:16 - Maximum difference between reference and actual voltage is 1.02 V 16:16 - Checking status of HVPA module in 6 drawer(s)... 16:16 - Checking status of HVPA channels in 6 drawer(s)... 16:16 - HV is stabilized in all channels. 16:16 - Finished task "Check HV" 16:17 - ECC is in state EccState.Ready with status EccStatus.NoError 16:17 - ECC temperature sensors: T1= 25.8, T2= 26.0, T3= 26.2, T4= 29.4 deg C 16:17 - 24 V power supply no. 1 is enabled with a current of 7.750 A. 16:17 - Checking high voltages... 16:17 - Starting task "Check HV" 16:17 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180621/NectarCAM.Run0861.NMC.xml 16:17 - Done 16:17 - Found 6 drawer(s). Reference voltage is between 959.43 V and 1289.01 V. Actual voltage is between 959.53 V and 1290.15 V. 16:17 - Maximum difference between reference and actual voltage is 1.14 V 16:17 - Checking status of HVPA module in 6 drawer(s)... 16:17 - Checking status of HVPA channels in 6 drawer(s)... 16:17 - HV is stabilized in all channels. 16:17 - Finished task "Check HV" 16:17 - Starting NMC 16:17 - Clearing PPS error counters 16:17 - Configuring calibration box... 16:17 - Configuring calibration box with leds=0x40 voltage=12.00 frequency=1000.0/1 central_current=0.0 duration=500 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 16:17 - Configuring TIB... 16:17 - Setting TIB forced mode to False 16:17 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 16:17 - Status: TibState.PpsStopped 16:17 - Alarms: AlarmVector.NoAlarm 16:17 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 16:17 - Setting TIB trigger mode to 0x8 = TriggerMask.SPhE 16:17 - Writing 8 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 16:17 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 16:17 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 16:17 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 16:17 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 16:17 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 16:17 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 16:17 - Writing False to serveur.TIB.Throttler.DisableThrottlerWR.DisableThrottlerWR_v 16:17 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR50us.MaxTriggersWR50us_v 16:17 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR1ms.MaxTriggersWR1ms_v 16:17 - Status: TibState.PpsStopped 16:17 - Alarms: AlarmVector.NoAlarm 16:17 - Closing TIB connection to camera server 16:17 - Connecting TIB to camera server at 10.10.0.251:222 16:17 - Starting TIB... 16:17 - Status: TibState.PpsStopped 16:17 - Alarms: AlarmVector.NoAlarm 16:17 - Resetting run 16:17 - Wait for UCTS external trigger before enabling trigger... 16:17 - Status: TibState.Standby 16:17 - Alarms: AlarmVector.NoAlarm 16:17 - Status: TibState.Standby 16:17 - Alarms: AlarmVector.NoAlarm 16:17 - Status: TibState.CoutingPps 16:17 - Alarms: AlarmVector.NoAlarm 16:17 - Starting TIB triggers... 16:17 - Enabling trigger 16:17 - Status: TibState.Running 16:17 - Alarms: AlarmVector.NoAlarm 16:17 - Starting flashes... 16:18 - Stopping TIB... 16:18 - Status: TibState.Running 16:18 - Alarms: AlarmVector.NoAlarm 16:18 - Disabling trigger 16:18 - Disabling PPS 16:18 - Status: TibState.PpsStopped 16:18 - Alarms: AlarmVector.NoAlarm 16:18 - Closing TIB connection to camera server 16:18 - Status: TibState.PpsStopped 16:18 - Alarms: AlarmVector.NoAlarm 16:18 - Run duration: 0:01:01 16:18 - Local camera triggers: 0 16:18 - Slow control triggers: 0 16:18 - Single photo-electron triggers: 49951 16:18 - Calibration triggers: 0 16:18 - Software triggers from UCTS: 0 16:18 - Auto-pedestal triggers: 391380 16:18 - Collected input triggers: 49951 16:18 - Busy triggers: 0 16:18 - Non-busy triggers sent to UCTS: 49951 16:18 - Camera event triggers sent to clusters: 49951 16:18 - Stopping NMC 16:18 - Found 0 PPS errors. 16:19 - Checking high voltages... 16:19 - Starting task "Check HV" 16:19 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180621/NectarCAM.Run0861.NMC.xml 16:19 - Done 16:19 - Found 6 drawer(s). Reference voltage is between 959.43 V and 1289.01 V. Actual voltage is between 959.53 V and 1290.15 V. 16:19 - Maximum difference between reference and actual voltage is 1.14 V 16:19 - Checking status of HVPA module in 6 drawer(s)... 16:19 - Checking status of HVPA channels in 6 drawer(s)... 16:19 - HV is stabilized in all channels. 16:19 - Finished task "Check HV"