13:25 - ECC is in state EccState.Ready with status EccStatus.NoError 13:25 - ECC temperature sensors: T1= 25.8, T2= 26.0, T3= 26.2, T4= 29.5 deg C 13:25 - 24 V power supply no. 1 is enabled with a current of 7.760 A. 13:25 - Checking high voltages... 13:25 - Starting task "Check HV" 13:25 - Checking reference voltages against 1100.000000 V 13:25 - Done 13:25 - Found 6 drawer(s). Reference voltage is between 1100.00 V and 1100.00 V. Actual voltage is between 1099.83 V and 1100.44 V. 13:25 - Maximum difference between reference and actual voltage is 0.44 V 13:25 - Checking status of HVPA module in 6 drawer(s)... 13:25 - Checking status of HVPA channels in 6 drawer(s)... 13:25 - HV is stabilized in all channels. 13:25 - Finished task "Check HV" 13:25 - Starting NMC 13:25 - Clearing PPS error counters 13:26 - Configuring calibration box... 13:26 - Configuring calibration box with leds=0x40 voltage=12.00 frequency=1000.0/1 central_current=0.0 duration=500 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 13:26 - Configuring TIB... 13:26 - Setting TIB forced mode to False 13:26 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 13:26 - Status: TibState.PpsStopped 13:26 - Alarms: AlarmVector.NoAlarm 13:26 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 13:26 - Setting TIB trigger mode to 0x8 = TriggerMask.SPhE 13:26 - Writing 8 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 13:26 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 13:26 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 13:26 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 13:26 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 13:26 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 13:26 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 13:26 - Writing False to serveur.TIB.Throttler.DisableThrottlerWR.DisableThrottlerWR_v 13:26 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR50us.MaxTriggersWR50us_v 13:26 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR1ms.MaxTriggersWR1ms_v 13:26 - Status: TibState.PpsStopped 13:26 - Alarms: AlarmVector.NoAlarm 13:26 - Closing TIB connection to camera server 13:26 - Connecting TIB to camera server at 10.10.0.251:222 13:26 - Starting TIB... 13:26 - Status: TibState.PpsStopped 13:26 - Alarms: AlarmVector.NoAlarm 13:26 - Resetting run 13:26 - Wait for UCTS external trigger before enabling trigger... 13:26 - Status: TibState.Standby 13:26 - Alarms: AlarmVector.NoAlarm 13:26 - Status: TibState.Standby 13:26 - Alarms: AlarmVector.NoAlarm 13:26 - Status: TibState.CoutingPps 13:26 - Alarms: AlarmVector.NoAlarm 13:26 - Starting TIB triggers... 13:26 - Enabling trigger 13:26 - Status: TibState.Running 13:26 - Alarms: AlarmVector.NoAlarm 13:26 - Starting flashes... 13:27 - Stopping TIB... 13:27 - Status: TibState.Running 13:27 - Alarms: AlarmVector.NoAlarm 13:27 - Disabling trigger 13:27 - Disabling PPS 13:27 - Status: TibState.PpsStopped 13:27 - Alarms: AlarmVector.NoAlarm 13:27 - Closing TIB connection to camera server 13:27 - Status: TibState.PpsStopped 13:27 - Alarms: AlarmVector.NoAlarm 13:27 - Run duration: 0:01:05 13:27 - Local camera triggers: 0 13:27 - Slow control triggers: 0 13:27 - Single photo-electron triggers: 49953 13:27 - Calibration triggers: 0 13:27 - Software triggers from UCTS: 0 13:27 - Auto-pedestal triggers: 419464 13:27 - Collected input triggers: 49953 13:27 - Busy triggers: 0 13:27 - Non-busy triggers sent to UCTS: 49953 13:27 - Camera event triggers sent to clusters: 49953 13:27 - Stopping NMC 13:27 - Found 0 PPS errors. 13:27 - Checking high voltages... 13:27 - Starting task "Check HV" 13:27 - Checking reference voltages against 1100.000000 V 13:27 - Done 13:27 - Found 6 drawer(s). Reference voltage is between 1100.00 V and 1100.00 V. Actual voltage is between 1099.83 V and 1100.44 V. 13:27 - Maximum difference between reference and actual voltage is 0.44 V 13:27 - Checking status of HVPA module in 6 drawer(s)... 13:27 - Checking status of HVPA channels in 6 drawer(s)... 13:27 - HV is stabilized in all channels. 13:27 - Finished task "Check HV"