12:08 - Checking high voltages... 12:08 - Starting task "Check HV" 12:08 - Checking reference voltages against 1400.000000 V 12:08 - Done 12:08 - Found 6 drawer(s). Reference voltage is between 1400.00 V and 1400.00 V. Actual voltage is between 1399.95 V and 1401.17 V. 12:08 - Maximum difference between reference and actual voltage is 1.78 V 12:08 - Checking status of HVPA module in 6 drawer(s)... 12:08 - Checking status of HVPA channels in 6 drawer(s)... 12:08 - HV is stabilized in all channels. 12:08 - Finished task "Check HV" 12:08 - ECC is in state EccState.Ready with status EccStatus.NoError 12:08 - ECC temperature sensors: T1= 25.8, T2= 26.0, T3= 26.1, T4= 29.6 deg C 12:08 - 24 V power supply no. 1 is enabled with a current of 7.790 A. 12:08 - Starting NMC 12:08 - Clearing PPS error counters 12:08 - Configuring calibration box... 12:08 - Configuring calibration box with leds=0x40 voltage=12.00 frequency=1000.0/1 central_current=0.0 duration=500 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 12:08 - Configuring TIB... 12:08 - Setting TIB forced mode to False 12:08 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 12:08 - Status: TibState.PpsStopped 12:08 - Alarms: AlarmVector.NoAlarm 12:08 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 12:08 - Setting TIB trigger mode to 0x8 = TriggerMask.SPhE 12:08 - Writing 8 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 12:08 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 12:08 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 12:08 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 12:08 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 12:08 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 12:08 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 12:08 - Writing False to serveur.TIB.Throttler.DisableThrottlerWR.DisableThrottlerWR_v 12:08 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR50us.MaxTriggersWR50us_v 12:08 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR1ms.MaxTriggersWR1ms_v 12:08 - Status: TibState.PpsStopped 12:08 - Alarms: AlarmVector.NoAlarm 12:08 - Closing TIB connection to camera server 12:08 - Connecting TIB to camera server at 10.10.0.251:222 12:08 - Starting TIB... 12:08 - Status: TibState.PpsStopped 12:08 - Alarms: AlarmVector.NoAlarm 12:08 - Resetting run 12:08 - Wait for UCTS external trigger before enabling trigger... 12:08 - Status: TibState.Standby 12:08 - Alarms: AlarmVector.NoAlarm 12:08 - Status: TibState.Standby 12:08 - Alarms: AlarmVector.NoAlarm 12:08 - Status: TibState.CoutingPps 12:08 - Alarms: AlarmVector.NoAlarm 12:08 - Starting TIB triggers... 12:08 - Enabling trigger 12:08 - Status: TibState.Running 12:08 - Alarms: AlarmVector.NoAlarm 12:08 - Starting flashes... 12:14 - Stopping TIB... 12:14 - Status: TibState.Running 12:14 - Alarms: AlarmVector.NoAlarm 12:14 - Disabling trigger 12:14 - Disabling PPS 12:14 - Status: TibState.PpsStopped 12:14 - Alarms: AlarmVector.NoAlarm 12:14 - Closing TIB connection to camera server 12:14 - Status: TibState.PpsStopped 12:14 - Alarms: AlarmVector.NoAlarm 12:14 - Run duration: 0:05:59 12:14 - Local camera triggers: 0 12:14 - Slow control triggers: 0 12:14 - Single photo-electron triggers: 49913 12:14 - Calibration triggers: 0 12:14 - Software triggers from UCTS: 0 12:14 - Auto-pedestal triggers: 2336781 12:14 - Collected input triggers: 49913 12:14 - Busy triggers: 0 12:14 - Non-busy triggers sent to UCTS: 49913 12:14 - Camera event triggers sent to clusters: 49913 12:14 - Stopping NMC 12:14 - Found 0 PPS errors. 12:14 - Checking high voltages... 12:14 - Starting task "Check HV" 12:14 - Checking reference voltages against 1400.000000 V 12:14 - Done 12:14 - Found 6 drawer(s). Reference voltage is between 1400.00 V and 1400.00 V. Actual voltage is between 1399.95 V and 1401.78 V. 12:14 - Maximum difference between reference and actual voltage is 1.78 V 12:14 - Checking status of HVPA module in 6 drawer(s)... 12:14 - Checking status of HVPA channels in 6 drawer(s)... 12:14 - HV is stabilized in all channels. 12:14 - Finished task "Check HV"