18:09 - ECC is in state EccState.Ready with status EccStatus.NoError 18:09 - ECC temperature sensors: T1= 25.4, T2= 25.6, T3= 25.8, T4= 29.1 deg C 18:09 - 24 V power supply no. 1 is enabled with a current of 7.750 A. 18:09 - Checking high voltages... 18:09 - Starting task "Check HV" 18:09 - Checking reference voltages against 1200.000000 V 18:09 - Done 18:09 - Found 6 drawer(s). Reference voltage is between 1200.00 V and 1200.00 V. Actual voltage is between 1199.87 V and 1201.70 V. 18:09 - Maximum difference between reference and actual voltage is 1.70 V 18:09 - Checking status of HVPA module in 6 drawer(s)... 18:09 - Checking status of HVPA channels in 6 drawer(s)... 18:09 - HV is stabilized in all channels. 18:09 - Finished task "Check HV" 18:09 - Starting NMC 18:09 - Clearing PPS error counters 18:09 - Configuring calibration box... 18:09 - Configuring calibration box with leds=0x40 voltage=10.00 frequency=1000.0/1 central_current=0.0 duration=500 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 18:10 - Configuring TIB... 18:10 - Setting TIB forced mode to False 18:10 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 18:10 - Status: TibState.PpsStopped 18:10 - Alarms: AlarmVector.NoAlarm 18:10 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 18:10 - Setting TIB trigger mode to 0x8 = TriggerMask.SPhE 18:10 - Writing 8 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 18:10 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 18:10 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 18:10 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 18:10 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 18:10 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 18:10 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 18:10 - Writing False to serveur.TIB.Throttler.DisableThrottlerWR.DisableThrottlerWR_v 18:10 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR50us.MaxTriggersWR50us_v 18:10 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR1ms.MaxTriggersWR1ms_v 18:10 - Status: TibState.PpsStopped 18:10 - Alarms: AlarmVector.NoAlarm 18:10 - Closing TIB connection to camera server 18:10 - Connecting TIB to camera server at 10.10.0.251:222 18:10 - Starting TIB... 18:10 - Status: TibState.PpsStopped 18:10 - Alarms: AlarmVector.NoAlarm 18:10 - Resetting run 18:10 - Wait for UCTS external trigger before enabling trigger... 18:10 - Status: TibState.Standby 18:10 - Alarms: AlarmVector.NoAlarm 18:10 - Status: TibState.Standby 18:10 - Alarms: AlarmVector.NoAlarm 18:10 - Status: TibState.CoutingPps 18:10 - Alarms: AlarmVector.NoAlarm 18:10 - Starting TIB triggers... 18:10 - Enabling trigger 18:10 - Status: TibState.Running 18:10 - Alarms: AlarmVector.NoAlarm 18:10 - Starting flashes... 18:11 - Stopping TIB... 18:11 - Status: TibState.Running 18:11 - Alarms: AlarmVector.NoAlarm 18:11 - Disabling trigger 18:11 - Disabling PPS 18:11 - Status: TibState.PpsStopped 18:11 - Alarms: AlarmVector.NoAlarm 18:11 - Closing TIB connection to camera server 18:11 - Status: TibState.PpsStopped 18:11 - Alarms: AlarmVector.NoAlarm 18:11 - Run duration: 0:01:06 18:11 - Local camera triggers: 0 18:11 - Slow control triggers: 0 18:11 - Single photo-electron triggers: 49925 18:11 - Calibration triggers: 0 18:11 - Software triggers from UCTS: 0 18:11 - Auto-pedestal triggers: 424485 18:11 - Collected input triggers: 49925 18:11 - Busy triggers: 0 18:11 - Non-busy triggers sent to UCTS: 49925 18:11 - Camera event triggers sent to clusters: 49925 18:11 - Checking high voltages... 18:11 - Starting task "Check HV" 18:11 - Checking reference voltages against 1200.000000 V 18:11 - Done 18:11 - Found 6 drawer(s). Reference voltage is between 1200.00 V and 1200.00 V. Actual voltage is between 1199.87 V and 1201.70 V. 18:11 - Maximum difference between reference and actual voltage is 1.70 V 18:11 - Checking status of HVPA module in 6 drawer(s)... 18:11 - Checking status of HVPA channels in 6 drawer(s)... 18:11 - HV is stabilized in all channels. 18:11 - Finished task "Check HV" 18:11 - Stopping NMC 18:11 - Found 0 PPS errors.