16:18 - Starting task "Configure NMC" 16:18 - Configuring modules with configuration /local/home/cta_test_bench/tests/2018/20180529/config_4modules_3NN.NMC.xml 16:18 - NMC is in state NmcState.Configured and knows of 4 drawer(s) 16:18 - Found 0 PPS errors. 16:18 - Finished task "Configure NMC" 16:18 - Checking high voltages... 16:18 - Starting task "Check HV" 16:18 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180529/config_4modules_3NN.NMC.xml 16:18 - Done 16:18 - Found 4 drawer(s). Reference voltage is between 0.00 V and 1227.22 V. Actual voltage is between 1.22 V and 1227.93 V. 16:18 - Maximum difference between reference and actual voltage is 1.21 V 16:18 - Checking status of HVPA module in 4 drawer(s)... 16:18 - Checking status of HVPA channels in 4 drawer(s)... 16:18 - HV is stabilized in all channels. 16:18 - Finished task "Check HV" 16:18 - Starting NMC 16:18 - Clearing PPS error counters 16:18 - Stopping flashes... 16:18 - Starting flashes... 16:19 - Configuring TIB... 16:19 - Setting TIB forced mode to False 16:19 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 16:19 - Status: TibState.PpsStopped 16:19 - Alarms: AlarmVector.NoAlarm 16:19 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 16:19 - Setting TIB trigger mode to 0x1 = TriggerMask.Mono 16:19 - Writing 1 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 16:19 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 16:19 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 16:19 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 16:19 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 16:19 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 16:19 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 16:19 - Writing False to serveur.TIB.Throttler.DisableThrottlerWR.DisableThrottlerWR_v 16:19 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR50us.MaxTriggersWR50us_v 16:19 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR1ms.MaxTriggersWR1ms_v 16:19 - Status: TibState.PpsStopped 16:19 - Alarms: AlarmVector.NoAlarm 16:19 - Closing TIB connection to camera server 16:19 - Connecting TIB to camera server at 10.10.0.251:222 16:19 - Starting TIB... 16:19 - Status: TibState.PpsStopped 16:19 - Alarms: AlarmVector.NoAlarm 16:19 - Resetting run 16:19 - Wait for UCTS external trigger before enabling trigger... 16:19 - Status: TibState.Standby 16:19 - Alarms: AlarmVector.NoAlarm 16:19 - Status: TibState.Standby 16:19 - Alarms: AlarmVector.NoAlarm 16:19 - Status: TibState.CoutingPps 16:19 - Alarms: AlarmVector.NoAlarm 16:19 - Starting TIB triggers... 16:19 - Enabling trigger 16:19 - Status: TibState.Running 16:19 - Alarms: AlarmVector.NoAlarm 16:35 - Stopping TIB... 16:35 - Status: TibState.Running 16:35 - Alarms: AlarmVector.NoAlarm 16:35 - Disabling trigger 16:35 - Disabling PPS 16:35 - Status: TibState.PpsStopped 16:35 - Alarms: AlarmVector.NoAlarm 16:35 - Closing TIB connection to camera server 16:35 - Status: TibState.PpsStopped 16:35 - Alarms: AlarmVector.NoAlarm 16:35 - Run duration: 0:15:22 16:35 - Local camera triggers: 0 16:35 - Slow control triggers: 0 16:35 - Single photo-electron triggers: 0 16:35 - Calibration triggers: 0 16:35 - Software triggers from UCTS: 0 16:35 - Auto-pedestal triggers: 6001478 16:35 - Collected input triggers: 9082 16:35 - Busy triggers: 0 16:35 - Non-busy triggers sent to UCTS: 9082 16:35 - Camera event triggers sent to clusters: 9082 16:35 - Status: TibState.PpsStopped 16:35 - Alarms: AlarmVector.NoAlarm 16:35 - Run duration: 0:15:22 16:35 - Local camera triggers: 0 16:35 - Slow control triggers: 0 16:35 - Single photo-electron triggers: 0 16:35 - Calibration triggers: 0 16:35 - Software triggers from UCTS: 0 16:35 - Auto-pedestal triggers: 6001478 16:35 - Collected input triggers: 9082 16:35 - Busy triggers: 0 16:35 - Non-busy triggers sent to UCTS: 9082 16:35 - Camera event triggers sent to clusters: 9082 16:36 - Stopping NMC 16:36 - Found 0 PPS errors. 16:36 - Checking high voltages... 16:36 - Starting task "Check HV" 16:36 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180529/config_4modules_3NN.NMC.xml 16:36 - Done 16:36 - Found 4 drawer(s). Reference voltage is between 0.00 V and 1227.22 V. Actual voltage is between 0.61 V and 1227.32 V. 16:36 - Maximum difference between reference and actual voltage is 1.69 V 16:36 - Checking status of HVPA module in 4 drawer(s)... 16:36 - Checking status of HVPA channels in 4 drawer(s)... 16:36 - HV is stabilized in all channels. 16:36 - Finished task "Check HV"