14:32 - Starting task "Configure NMC" 14:32 - Configuring modules with configuration /local/home/cta_test_bench/tests/2018/20180529/config_4modules_3NN.NMC.xml 14:32 - NMC is in state NmcState.Configured and knows of 4 drawer(s) 14:32 - Found 0 PPS errors. 14:32 - Finished task "Configure NMC" 14:32 - Checking high voltages... 14:32 - Starting task "Check HV" 14:32 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180529/config_4modules_3NN.NMC.xml 14:32 - Reference voltage of channel 5 in drawer #116: expected 1190.92, read 0.00 14:32 - Reference voltage of channel 0 in drawer #149: expected 951.32, read 0.00 14:32 - Reference voltage of channel 1 in drawer #149: expected 993.09, read 0.00 14:32 - Reference voltage of channel 2 in drawer #149: expected 988.47, read 0.00 14:32 - Reference voltage of channel 4 in drawer #149: expected 988.76, read 0.00 14:32 - Reference voltage of channel 5 in drawer #149: expected 971.32, read 0.00 14:32 - Done 14:32 - Found 4 drawer(s). Reference voltage is between 0.00 V and 1227.22 V. Actual voltage is between 0.00 V and 370.88 V. 14:32 - Maximum difference between reference and actual voltage is 853.90 V 14:32 - Checking status of HVPA module in 4 drawer(s)... 14:32 - HVPA module in drawer 116 has a status of 0x5f! 14:32 - Checking status of HVPA channels in 4 drawer(s)... 14:32 - HVPA channel 5 of drawer 116 has status 0x8001! 14:32 - Resetting HVPA channel 5 of drawer 116... 14:32 - HV was locked in 1 channel(s), was in rise default in 0 channel(s) and was still in progress in 21 channel(s) 14:32 - Finished task "Check HV" 14:33 - Enabling high voltages... 14:33 - Starting task "Enable HV" 14:33 - Setting HV to 100.0 V 14:33 - Check of HVPA failed: expected 100.00, read 1158.14 14:33 - Check of HVPA failed: expected 100.00, read 0.00 14:33 - Check of HVPA failed: expected 100.00, read 0.00 14:33 - Checking status of HVPA channels in 4 drawer(s)... 14:33 - HVPA channel 5 of drawer 116 has status 0x8001! 14:33 - Resetting HVPA channel 5 of drawer 116... 14:33 - HV was locked in 1 channel(s), was in rise default in 0 channel(s) and was still in progress in 24 channel(s) 14:33 - Setting HV to nominal values... 14:33 - Setting channel 0 voltages to [1092.65, 1154.16, 1078.12, 951.32] 14:33 - Setting channel 1 voltages to [1117.69, 1164.29, 1104.93, 993.09] 14:33 - Setting channel 2 voltages to [1061.26, 1158.46, 1075.89, 988.47] 14:33 - Setting channel 3 voltages to [1158.14, 1119.57, 1145.38, 982.15] 14:33 - Setting channel 4 voltages to [0.0, 1166.64, 1184.94, 988.76] 14:33 - Setting channel 5 voltages to [1171.44, 1179.65, 1190.92, 971.32] 14:33 - Setting channel 6 voltages to [1102.07, 1097.92, 1227.22, 969.17] 14:33 - Checking status of HVPA channels in 4 drawer(s)... 14:33 - HV was locked in 0 channel(s), was in rise default in 0 channel(s) and was still in progress in 25 channel(s) 14:33 - Check of 'NectarFrontEnd_116.Hvpa.Hvpa4.Voltage' failed: expected 1184.94, read 100 14:33 - Check of 'NectarFrontEnd_116.Hvpa.Hvpa5.Voltage' failed: expected 1190.92, read 100 14:33 - Finished task "Enable HV" 14:33 - Checking high voltages... 14:33 - Starting task "Check HV" 14:33 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180529/config_4modules_3NN.NMC.xml 14:33 - Reference voltage of channel 3 in drawer #116: expected 1145.38, read 1147.89 14:33 - Done 14:33 - Found 4 drawer(s). Reference voltage is between 0.00 V and 1227.22 V. Actual voltage is between 59.78 V and 1227.93 V. 14:33 - Maximum difference between reference and actual voltage is 600.44 V 14:33 - Checking status of HVPA module in 4 drawer(s)... 14:33 - Checking status of HVPA channels in 4 drawer(s)... 14:33 - HV was locked in 0 channel(s), was in rise default in 0 channel(s) and was still in progress in 7 channel(s) 14:33 - Finished task "Check HV" 14:34 - Checking high voltages... 14:34 - Starting task "Check HV" 14:34 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180529/config_4modules_3NN.NMC.xml 14:34 - Reference voltage of channel 3 in drawer #116: expected 1145.38, read 1147.89 14:34 - Done 14:34 - Found 4 drawer(s). Reference voltage is between 0.00 V and 1227.22 V. Actual voltage is between 17.69 V and 1227.93 V. 14:34 - Maximum difference between reference and actual voltage is 17.08 V 14:34 - Checking status of HVPA module in 4 drawer(s)... 14:34 - Checking status of HVPA channels in 4 drawer(s)... 14:34 - HV is stabilized in all channels. 14:34 - Finished task "Check HV" 14:34 - Checking high voltages... 14:34 - Starting task "Check HV" 14:34 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180529/config_4modules_3NN.NMC.xml 14:34 - Reference voltage of channel 3 in drawer #116: expected 1145.38, read 1147.89 14:34 - Done 14:34 - Found 4 drawer(s). Reference voltage is between 0.00 V and 1227.22 V. Actual voltage is between 11.59 V and 1227.93 V. 14:34 - Maximum difference between reference and actual voltage is 11.59 V 14:34 - Checking status of HVPA module in 4 drawer(s)... 14:34 - Checking status of HVPA channels in 4 drawer(s)... 14:34 - HV is stabilized in all channels. 14:34 - Finished task "Check HV" 14:34 - Starting NMC 14:34 - Clearing PPS error counters 14:36 - Configuring TIB... 14:36 - Setting TIB forced mode to False 14:36 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 14:36 - Status: TibState.PpsStopped 14:36 - Alarms: AlarmVector.NoAlarm 14:36 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 14:36 - Setting TIB trigger mode to 0x1 = TriggerMask.Mono 14:36 - Writing 1 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 14:36 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 14:36 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 14:36 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 14:36 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 14:36 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 14:36 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 14:36 - Writing False to serveur.TIB.Throttler.DisableThrottlerWR.DisableThrottlerWR_v 14:36 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR50us.MaxTriggersWR50us_v 14:36 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR1ms.MaxTriggersWR1ms_v 14:36 - Status: TibState.PpsStopped 14:36 - Alarms: AlarmVector.NoAlarm 14:36 - Closing TIB connection to camera server 14:36 - Connecting TIB to camera server at 10.10.0.251:222 14:36 - Starting TIB... 14:36 - Status: TibState.PpsStopped 14:36 - Alarms: AlarmVector.NoAlarm 14:36 - Resetting run 14:36 - Wait for UCTS external trigger before enabling trigger... 14:36 - Status: TibState.Standby 14:36 - Alarms: AlarmVector.NoAlarm 14:36 - Status: TibState.Standby 14:36 - Alarms: AlarmVector.NoAlarm 14:36 - Status: TibState.Armed 14:36 - Alarms: AlarmVector.NoAlarm 14:37 - Starting TIB triggers... 14:37 - Enabling trigger 14:37 - Status: TibState.Running 14:37 - Alarms: AlarmVector.NoAlarm 14:38 - Stopping TIB... 14:38 - Status: TibState.Running 14:38 - Alarms: AlarmVector.NoAlarm 14:38 - Disabling trigger 14:38 - Disabling PPS 14:38 - Status: TibState.PpsStopped 14:38 - Alarms: AlarmVector.NoAlarm 14:38 - Closing TIB connection to camera server 14:39 - Stopping NMC 14:39 - Found 0 PPS errors. 14:40 - Status: TibState.PpsStopped 14:40 - Alarms: AlarmVector.NoAlarm 14:40 - Run duration: 0:02:08 14:40 - Local camera triggers: 0 14:40 - Slow control triggers: 0 14:40 - Single photo-electron triggers: 12712 14:40 - Calibration triggers: 0 14:40 - Software triggers from UCTS: 0 14:40 - Auto-pedestal triggers: 826198 14:40 - Collected input triggers: 668403 14:40 - Busy triggers: 56296 14:40 - Non-busy triggers sent to UCTS: 612204 14:40 - Camera event triggers sent to clusters: 612204 14:40 - Checking high voltages... 14:40 - Starting task "Check HV" 14:40 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180529/config_4modules_3NN.NMC.xml 14:40 - Reference voltage of channel 3 in drawer #116: expected 1145.38, read 1147.89 14:40 - Done 14:40 - Found 4 drawer(s). Reference voltage is between 0.00 V and 1227.22 V. Actual voltage is between 2.44 V and 1228.54 V. 14:40 - Maximum difference between reference and actual voltage is 2.44 V 14:40 - Checking status of HVPA module in 4 drawer(s)... 14:40 - Checking status of HVPA channels in 4 drawer(s)... 14:40 - HV is stabilized in all channels. 14:40 - Finished task "Check HV" 14:40 - Checking high voltages... 14:40 - Starting task "Check HV" 14:40 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180529/config_4modules_3NN.NMC.xml 14:40 - Reference voltage of channel 3 in drawer #116: expected 1145.38, read 1147.89 14:40 - Done 14:40 - Found 4 drawer(s). Reference voltage is between 0.00 V and 1227.22 V. Actual voltage is between 2.44 V and 1228.54 V. 14:40 - Maximum difference between reference and actual voltage is 1.83 V 14:40 - Checking status of HVPA module in 4 drawer(s)... 14:40 - Checking status of HVPA channels in 4 drawer(s)... 14:40 - HV is stabilized in all channels. 14:40 - Finished task "Check HV"