18:13 - NMC is in state NmcState.Configured and knows of 6 drawer(s) 18:13 - Found 0 PPS errors. 18:13 - Finished task "Configure NMC" 18:13 - Checking high voltages... 18:13 - Starting task "Check HV" 18:13 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180524/NectarCAM.Run0830.NMC.xml 18:13 - Done 18:13 - Found 6 drawer(s). Reference voltage is between 951.32 V and 1227.22 V. Actual voltage is between 1002.23 V and 1255.99 V. 18:13 - Maximum difference between reference and actual voltage is 51.97 V 18:13 - Checking status of HVPA module in 6 drawer(s)... 18:13 - Checking status of HVPA channels in 6 drawer(s)... 18:13 - HV was locked in 0 channel(s), was in rise default in 0 channel(s) and was still in progress in 42 channel(s) 18:13 - Finished task "Check HV" 18:14 - Checking high voltages... 18:14 - Starting task "Check HV" 18:14 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180524/NectarCAM.Run0830.NMC.xml 18:14 - Done 18:14 - Found 6 drawer(s). Reference voltage is between 951.32 V and 1227.22 V. Actual voltage is between 968.07 V and 1227.32 V. 18:14 - Maximum difference between reference and actual voltage is 17.81 V 18:14 - Checking status of HVPA module in 6 drawer(s)... 18:14 - Checking status of HVPA channels in 6 drawer(s)... 18:14 - HV was locked in 0 channel(s), was in rise default in 0 channel(s) and was still in progress in 8 channel(s) 18:14 - Finished task "Check HV" 18:14 - Checking high voltages... 18:14 - Starting task "Check HV" 18:14 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180524/NectarCAM.Run0830.NMC.xml 18:14 - Done 18:14 - Found 6 drawer(s). Reference voltage is between 951.32 V and 1227.22 V. Actual voltage is between 951.60 V and 1227.32 V. 18:14 - Maximum difference between reference and actual voltage is 0.73 V 18:14 - Checking status of HVPA module in 6 drawer(s)... 18:14 - Checking status of HVPA channels in 6 drawer(s)... 18:14 - HV is stabilized in all channels. 18:14 - Finished task "Check HV" 18:14 - Starting NMC 18:14 - Clearing PPS error counters 18:15 - Configuring TIB... 18:15 - Setting TIB forced mode to False 18:15 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 18:15 - Status: TibState.PpsStopped 18:15 - Alarms: AlarmVector.NoAlarm 18:15 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 18:15 - Setting TIB trigger mode to 0x8 = TriggerMask.SPhE 18:15 - Writing 8 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 18:15 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 18:15 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 18:15 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 18:15 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 18:15 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 18:15 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 18:15 - Writing False to serveur.TIB.Throttler.DisableThrottlerWR.DisableThrottlerWR_v 18:15 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR50us.MaxTriggersWR50us_v 18:15 - Writing 255 to serveur.TIB.Throttler.MaxTriggersWR1ms.MaxTriggersWR1ms_v 18:15 - Status: TibState.PpsStopped 18:15 - Alarms: AlarmVector.NoAlarm 18:15 - Closing TIB connection to camera server 18:15 - Connecting TIB to camera server at 10.10.0.251:222 18:15 - Starting TIB... 18:15 - Status: TibState.PpsStopped 18:15 - Alarms: AlarmVector.NoAlarm 18:15 - Resetting run 18:15 - Wait for UCTS external trigger before enabling trigger... 18:15 - Status: TibState.Standby 18:15 - Alarms: AlarmVector.NoAlarm 18:15 - Status: TibState.Standby 18:15 - Alarms: AlarmVector.NoAlarm 18:15 - Status: TibState.CoutingPps 18:15 - Alarms: AlarmVector.NoAlarm 18:15 - Starting TIB triggers... 18:15 - Enabling trigger 18:15 - Status: TibState.Running 18:15 - Alarms: AlarmVector.NoAlarm 18:15 - Configuring calibration box... 18:15 - Configuring calibration box with leds=0x358 voltage=9.75 frequency=5000.0/1 central_current=0.0 duration=100 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=False enabled=False 18:15 - Starting flashes... 18:15 - Stopping TIB... 18:15 - Status: TibState.Running 18:15 - Alarms: AlarmVector.NoAlarm 18:15 - Disabling trigger 18:15 - Disabling PPS 18:15 - Status: TibState.PpsStopped 18:15 - Alarms: AlarmVector.NoAlarm 18:15 - Closing TIB connection to camera server 18:15 - Status: TibState.PpsStopped 18:15 - Alarms: AlarmVector.NoAlarm 18:15 - Run duration: 0:00:41 18:15 - Local camera triggers: 0 18:15 - Slow control triggers: 0 18:15 - Single photo-electron triggers: 49992 18:15 - Calibration triggers: 0 18:15 - Software triggers from UCTS: 0 18:15 - Auto-pedestal triggers: 262896 18:15 - Collected input triggers: 49992 18:15 - Busy triggers: 0 18:15 - Non-busy triggers sent to UCTS: 49992 18:15 - Camera event triggers sent to clusters: 49992 18:15 - Stopping NMC 18:15 - Found 0 PPS errors. 18:16 - Checking high voltages... 18:16 - Starting task "Check HV" 18:16 - Checking reference voltages against /local/home/cta_test_bench/tests/2018/20180524/NectarCAM.Run0830.NMC.xml 18:16 - Done 18:16 - Found 6 drawer(s). Reference voltage is between 951.32 V and 1227.22 V. Actual voltage is between 950.99 V and 1227.93 V. 18:16 - Maximum difference between reference and actual voltage is 0.60 V 18:16 - Checking status of HVPA module in 6 drawer(s)... 18:16 - Checking status of HVPA channels in 6 drawer(s)...