14:42 - ECC is in state EccState.Ready with status EccStatus.NoError 14:42 - ECC temperature sensors: T1= 34.1, T2= 24.9, T3= 24.0, T4= 24.2 deg C 14:42 - 24 V power supply no. 1 is enabled with a current of 9.470 A. 14:42 - Checking high voltages... 14:42 - Starting task "Check HV" 14:42 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180330/config_1module_SPE_Ibof45_DelayBusy10_newHV.NMC.xml 14:42 - Done 14:42 - Found 1 drawer(s). Reference voltage is between 968.11 V and 1003.39 V. Actual voltage is between 968.68 V and 1004.06 V. 14:42 - Maximum difference between reference and actual voltage is 0.67 V 14:42 - Checking status of HVPA module in 1 drawer(s)... 14:42 - Checking status of HVPA channels in 1 drawer(s)... 14:42 - HV is stabilized in all channels. 14:42 - Finished task "Check HV" 14:42 - Starting NMC 14:42 - Clearing PPS error counters 14:42 - Configuring TIB... 14:42 - Setting TIB forced mode to False 14:42 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 14:42 - Status: TibState.PpsStopped 14:42 - Alarms: AlarmVector.NoAlarm 14:42 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 14:42 - Setting TIB trigger mode to 0x8 = TriggerMask.SPhE 14:42 - Writing 8 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 14:42 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 14:42 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 14:42 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 14:42 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 14:42 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 14:42 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 14:42 - Status: TibState.PpsStopped 14:42 - Alarms: AlarmVector.NoAlarm 14:42 - Closing TIB connection to camera server 14:42 - Connecting TIB to camera server at 10.10.0.251:222 14:42 - Starting TIB... 14:42 - Status: TibState.PpsStopped 14:42 - Alarms: AlarmVector.NoAlarm 14:42 - Resetting run 14:42 - Wait for UCTS external trigger before enabling trigger... 14:42 - Status: TibState.Standby 14:42 - Alarms: AlarmVector.NoAlarm 14:42 - Status: TibState.Standby 14:42 - Alarms: AlarmVector.NoAlarm 14:42 - Status: TibState.CoutingPps 14:42 - Alarms: AlarmVector.NoAlarm 14:42 - Starting TIB triggers... 14:42 - Enabling trigger 14:42 - Status: TibState.Running 14:42 - Alarms: AlarmVector.NoAlarm iINFO Scanning 1 + 19 frequencies of the calibration box INFO Periods: [10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000] INFO Setting LED mask to 0x0 INFO Configuring calibration box with leds=0x0 voltage=8.00 frequency=1000.0/1.0 central_current=0.0 duration=0 width=1 lemo_out=True fiber1_out=True fiber2_out=False lemo_in=False enabled=False INFO Starting flashes... INFO Stopping flashes... INFO Setting LED mask to 0x358 INFO Setting LED voltage to 10.000000 INFO Setting frequency to 100000.000000 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 50000.000000 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 33333.333333 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 25000.000000 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 20000.000000 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 16666.666667 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 14285.714286 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 12500.000000 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 11111.111111 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 10000.000000 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 5000.000000 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 3333.333333 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 2500.000000 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 2000.000000 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 1666.666667 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 1428.571429 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 1250.000000 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 1111.111111 Hz INFO Starting flashes... INFO Stopping flashes... INFO Setting frequency to 1000.000000 Hz INFO Starting flashes... INFO Stopping flashes... INFO Scan took 0:05:14.498601 14:48 - Stopping TIB... 14:48 - Status: TibState.Running 14:48 - Alarms: AlarmVector.NoAlarm 14:48 - Disabling trigger 14:48 - Disabling PPS 14:48 - Status: TibState.PpsStopped 14:48 - Alarms: AlarmVector.NoAlarm 14:48 - Closing TIB connection to camera server 14:48 - Status: TibState.PpsStopped 14:48 - Alarms: AlarmVector.NoAlarm 14:48 - Run duration: 0:05:36 14:48 - Local camera triggers: 0 14:48 - Slow control triggers: 0 14:48 - Single photo-electron triggers: 955444 14:48 - Calibration triggers: 0 14:48 - Software triggers from UCTS: 0 14:48 - Auto-pedestal triggers: 2181425 14:48 - Collected input triggers: 955444 14:48 - Busy triggers: 0 14:48 - Non-busy triggers sent to UCTS: 955444 14:48 - Camera event triggers sent to clusters: 955444 14:48 - Stopping NMC 14:48 - Found 0 PPS errors. 14:48 - Checking high voltages... 14:48 - Starting task "Check HV" 14:48 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180330/config_1module_SPE_Ibof45_DelayBusy10_newHV.NMC.xml 14:48 - Done 14:48 - Found 1 drawer(s). Reference voltage is between 968.11 V and 1003.39 V. Actual voltage is between 969.29 V and 1003.45 V. 14:48 - Maximum difference between reference and actual voltage is 1.18 V 14:48 - Checking status of HVPA module in 1 drawer(s)... 14:48 - Checking status of HVPA channels in 1 drawer(s)... 14:48 - HV is stabilized in all channels. 14:48 - Finished task "Check HV"