13:49 - Checking high voltages... 13:49 - Starting task "Check HV" 13:49 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180326/config_12modules_SPE_2GHz_nf60.NMC.xml 13:49 - Done 13:50 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1262.89 V. Actual voltage is between 177.51 V and 623.42 V. 13:50 - Maximum difference between reference and actual voltage is 994.56 V 13:50 - Checking status of HVPA module in 12 drawer(s)... 13:50 - Checking status of HVPA channels in 12 drawer(s)... 13:50 - HV was locked in 0 channel(s), was in rise default in 0 channel(s) and was still in progress in 84 channel(s) 13:50 - Finished task "Check HV" 13:51 - Checking high voltages... 13:51 - Starting task "Check HV" 13:51 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180326/config_12modules_SPE_2GHz_nf60.NMC.xml 13:51 - Done 13:51 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1262.89 V. Actual voltage is between 968.68 V and 1263.31 V. 13:51 - Maximum difference between reference and actual voltage is 1.16 V 13:51 - Checking status of HVPA module in 12 drawer(s)... 13:51 - Checking status of HVPA channels in 12 drawer(s)... 13:51 - HV is stabilized in all channels. 13:51 - Finished task "Check HV" 13:51 - Starting NMC 13:51 - Clearing PPS error counters 13:51 - ECC is in state EccState.Ready with status EccStatus.NoError 13:51 - ECC temperature sensors: T1= 34.3, T2= 24.5, T3= 23.9, T4= 24.0 deg C 13:51 - 24 V power supply no. 1 is enabled with a current of 9.790 A. 13:51 - Configuring calibration box... 13:51 - Configuring calibration box with leds=0x0 voltage=9.25 frequency=300.0/300 central_current=0.0 duration=0 width=1 lemo_out=True fiber1_out=True fiber2_out=True lemo_in=True enabled=True 13:51 - Configuring TIB... 13:51 - Setting TIB forced mode to False 13:51 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 13:51 - Status: TibState.PpsStopped 13:51 - Alarms: AlarmVector.NoAlarm 13:51 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 13:51 - Setting TIB trigger mode to 0x8 = TriggerMask.SPhE 13:51 - Writing 8 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 13:51 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 13:51 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 13:51 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 13:51 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 13:51 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 13:51 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 13:51 - Status: TibState.PpsStopped 13:51 - Alarms: AlarmVector.NoAlarm 13:51 - Closing TIB connection to camera server 13:51 - Connecting TIB to camera server at 10.10.0.251:222 13:51 - Starting TIB... 13:51 - Status: TibState.PpsStopped 13:51 - Alarms: AlarmVector.NoAlarm 13:51 - Resetting run 13:51 - Wait for UCTS external trigger before enabling trigger... 13:51 - Status: TibState.Standby 13:51 - Alarms: AlarmVector.NoAlarm 13:51 - Status: TibState.Standby 13:51 - Alarms: AlarmVector.NoAlarm 13:51 - Status: TibState.CoutingPps 13:51 - Alarms: AlarmVector.NoAlarm 13:51 - Starting TIB triggers... 13:51 - Enabling trigger 13:51 - Status: TibState.Running 13:51 - Alarms: AlarmVector.NoAlarm 13:51 - Status: TibState.Running ConnectionStatus: True 13:51 - Alarms: AlarmVector.NoAlarm 13:51 - Temperature: 36.6875 13:51 - Local camera rate: 0.0 Hz 13:51 - Stereo trigger rate: 0.0 Hz 13:51 - SPE trigger rate: 10150.0 Hz 13:51 - Calibration trigger rate: 0.0 Hz 13:51 - Software trigger rate: 0.0 Hz 13:51 - Auto-pedestal trigger rate: 6596.0 Hz 13:51 - Collected trigger rate: 10083.0 Hz 13:51 - Busy rate: 693.0 Hz 13:51 - Camera trigger rate: 9390.0 Hz 13:51 - Stopping TIB... 13:51 - Status: TibState.Running 13:51 - Alarms: AlarmVector.NoAlarm 13:51 - Disabling trigger 13:51 - Disabling PPS 13:51 - Status: TibState.PpsStopped 13:51 - Alarms: AlarmVector.NoAlarm 13:51 - Closing TIB connection to camera server 13:51 - Status: TibState.PpsStopped 13:51 - Alarms: AlarmVector.NoAlarm 13:51 - Run duration: 0:00:18 13:51 - Local camera triggers: 0 13:51 - Slow control triggers: 0 13:51 - Single photo-electron triggers: 175175 13:51 - Calibration triggers: 0 13:51 - Software triggers from UCTS: 0 13:51 - Auto-pedestal triggers: 113752 13:51 - Collected input triggers: 125142 13:51 - Busy triggers: 8760 13:51 - Non-busy triggers sent to UCTS: 116389 13:51 - Camera event triggers sent to clusters: 116389 13:51 - Stopping NMC 13:51 - Found 0 PPS errors. 13:51 - Checking high voltages... 13:51 - Starting task "Check HV" 13:51 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180326/config_12modules_SPE_2GHz_nf60.NMC.xml 13:51 - Done 13:51 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1262.89 V. Actual voltage is between 969.29 V and 1263.92 V. 13:51 - Maximum difference between reference and actual voltage is 1.54 V 13:51 - Checking status of HVPA module in 12 drawer(s)... 13:51 - Checking status of HVPA channels in 12 drawer(s)... 13:51 - HV is stabilized in all channels. 13:51 - Finished task "Check HV"