08:45 - ECC is in state EccState.Ready with status EccStatus.NoError 08:45 - ECC temperature sensors: T1= 34.0, T2= 24.3, T3= 23.5, T4= 23.7 deg C 08:45 - 24 V power supply no. 1 is enabled with a current of 9.710 A. 08:47 - Stopping NMC 08:47 - Found 0 PPS errors. 08:47 - Checking high voltages... 08:47 - Starting task "Check HV" 08:47 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180319/config_12modules_SPE.NMC.xml 08:47 - Done 08:47 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.34 V. 08:47 - Maximum difference between reference and actual voltage is 1.66 V 08:47 - Checking status of HVPA module in 12 drawer(s)... 08:47 - Checking status of HVPA channels in 12 drawer(s)... 08:47 - HV is stabilized in all channels. 08:47 - Finished task "Check HV" 08:47 - Starting NMC 08:47 - Clearing PPS error counters 08:47 - Configuring TIB... 08:47 - Setting TIB forced mode to False 08:47 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 08:47 - Status: TibState.PpsStopped 08:47 - Alarms: AlarmVector.NoAlarm 08:47 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 08:47 - Setting TIB trigger mode to 0x8 = TriggerMask.SPhE 08:47 - Writing 8 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 08:47 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 08:47 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 08:47 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 08:47 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 08:47 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 08:47 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 08:47 - Status: TibState.PpsStopped 08:47 - Alarms: AlarmVector.NoAlarm 08:47 - Closing TIB connection to camera server 08:47 - Connecting TIB to camera server at 10.10.0.251:222 08:47 - Starting TIB... 08:47 - Status: TibState.PpsStopped 08:47 - Alarms: AlarmVector.NoAlarm 08:47 - Resetting run 08:47 - Wait for UCTS external trigger before enabling trigger... 08:47 - Status: TibState.Standby 08:47 - Alarms: AlarmVector.NoAlarm 08:47 - Status: TibState.Standby 08:47 - Alarms: AlarmVector.NoAlarm 08:47 - Status: TibState.Armed 08:47 - Alarms: AlarmVector.NoAlarm 08:47 - Starting TIB triggers... 08:47 - Enabling trigger 08:47 - Status: TibState.Running 08:47 - Alarms: AlarmVector.NoAlarm INFO Scanning voltage of the calibration box from 14.000000 V to 15.000000 V INFO Setting LED mask to 0x0 INFO Configuring calibration box with leds=0x0 voltage=14.00 frequency=1000/1 central_current=0.0 duration=0 width=1 lemo_out=True fiber1_out=True fiber2_out=False lemo_in=False enabled=False INFO Starting flashes... INFO Stopping flashes... INFO Setting LED mask to 0x358 INFO Setting voltage to 14.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Scan took 0:00:31.483187 08:49 - Stopping TIB... 08:49 - Status: TibState.Running 08:49 - Alarms: AlarmVector.NoAlarm 08:49 - Disabling trigger 08:49 - Disabling PPS 08:49 - Status: TibState.PpsStopped 08:49 - Alarms: AlarmVector.NoAlarm 08:49 - Closing TIB connection to camera server 08:49 - Status: TibState.PpsStopped 08:49 - Alarms: AlarmVector.NoAlarm 08:49 - Run duration: 0:01:20 08:49 - Local camera triggers: 0 08:49 - Slow control triggers: 0 08:49 - Single photo-electron triggers: 12108 08:49 - Calibration triggers: 0 08:49 - Software triggers from UCTS: 0 08:49 - Auto-pedestal triggers: 515968 08:49 - Collected input triggers: 12108 08:49 - Busy triggers: 0 08:49 - Non-busy triggers sent to UCTS: 12108 08:49 - Camera event triggers sent to clusters: 12108 08:49 - Stopping NMC 08:49 - Found 0 PPS errors. 08:49 - Checking high voltages... 08:49 - Starting task "Check HV" 08:49 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180319/config_12modules_SPE.NMC.xml 08:49 - Done 08:49 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.34 V. 08:49 - Maximum difference between reference and actual voltage is 1.66 V 08:49 - Checking status of HVPA module in 12 drawer(s)... 08:49 - Checking status of HVPA channels in 12 drawer(s)... 08:49 - HV is stabilized in all channels. 08:49 - Finished task "Check HV"