16:09 - Resetting NMC 16:09 - Starting task "Configure NMC" 16:09 - Configuring modules with configuration /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_6pe.NMC.xml 16:10 - NMC is in state NmcState.Configured and knows of 12 drawer(s) 16:10 - Found 0 PPS errors. 16:10 - Finished task "Configure NMC" 16:10 - Checking high voltages... 16:10 - Starting task "Check HV" 16:10 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_6pe.NMC.xml 16:10 - Done 16:10 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.34 V. 16:10 - Maximum difference between reference and actual voltage is 1.66 V 16:10 - Checking status of HVPA module in 12 drawer(s)... 16:10 - Checking status of HVPA channels in 12 drawer(s)... 16:10 - HV is stabilized in all channels. 16:10 - Finished task "Check HV" 16:10 - Starting NMC 16:10 - Clearing PPS error counters 16:10 - Closing TIB connection to camera server 16:10 - Connecting TIB to camera server at 10.10.0.251:222 16:10 - Starting TIB... 16:10 - Status: TibState.PpsStopped 16:10 - Alarms: AlarmVector.NoAlarm 16:10 - Resetting run 16:10 - Wait for UCTS external trigger before enabling trigger... 16:10 - Status: TibState.Standby 16:10 - Alarms: AlarmVector.NoAlarm 16:10 - Status: TibState.Standby 16:10 - Alarms: AlarmVector.NoAlarm 16:10 - Status: TibState.Armed 16:10 - Alarms: AlarmVector.NoAlarm 16:11 - Stopping TIB... 16:11 - Status: TibState.CoutingPps 16:11 - Alarms: AlarmVector.NoAlarm 16:11 - Disabling trigger 16:11 - Failed to call DisableTrigger: Bad statuses are present 16:11 - Configuring TIB... 16:11 - Setting TIB forced mode to False 16:11 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 16:11 - Status: TibState.CoutingPps 16:11 - Alarms: AlarmVector.NoAlarm 16:11 - Disabling PPS 16:11 - Failed to call DisablePPS: Bad statuses are present 16:11 - Starting TIB triggers... 16:11 - Enabling trigger 16:11 - Status: TibState.Running 16:11 - Alarms: AlarmVector.NoAlarm 16:12 - Status: TibState.Running ConnectionStatus: True 16:12 - Alarms: AlarmVector.NoAlarm 16:12 - Temperature: 37.0 16:12 - Local camera rate: 0.0 Hz 16:12 - Stereo trigger rate: 0.0 Hz 16:12 - SPE trigger rate: 0.0 Hz 16:12 - Calibration trigger rate: 0.0 Hz 16:12 - Software trigger rate: 0.0 Hz 16:12 - Auto-pedestal trigger rate: 6319.0 Hz 16:12 - Collected trigger rate: 10.0 Hz 16:12 - Busy rate: 0.0 Hz 16:12 - Camera trigger rate: 10.0 Hz 16:13 - Status: TibState.Running ConnectionStatus: True 16:13 - Alarms: AlarmVector.NoAlarm 16:13 - Temperature: 37.0 16:13 - Local camera rate: 0.0 Hz 16:13 - Stereo trigger rate: 0.0 Hz 16:13 - SPE trigger rate: 0.0 Hz 16:13 - Calibration trigger rate: 0.0 Hz 16:13 - Software trigger rate: 0.0 Hz 16:13 - Auto-pedestal trigger rate: 6548.0 Hz 16:13 - Collected trigger rate: 1.0 Hz 16:13 - Busy rate: 0.0 Hz 16:13 - Camera trigger rate: 1.0 Hz 16:14 - Stopping TIB... 16:14 - Status: TibState.Running 16:14 - Alarms: AlarmVector.NoAlarm 16:14 - Disabling trigger 16:14 - Disabling PPS 16:14 - Status: TibState.PpsStopped 16:14 - Alarms: AlarmVector.NoAlarm 16:14 - Closing TIB connection to camera server 16:14 - Status: TibState.PpsStopped 16:14 - Alarms: AlarmVector.NoAlarm 16:14 - Run duration: 0:03:27 16:14 - Local camera triggers: 0 16:14 - Slow control triggers: 0 16:14 - Single photo-electron triggers: 0 16:14 - Calibration triggers: 0 16:14 - Software triggers from UCTS: 0 16:14 - Auto-pedestal triggers: 1347523 16:14 - Collected input triggers: 640 16:14 - Busy triggers: 0 16:14 - Non-busy triggers sent to UCTS: 640 16:14 - Camera event triggers sent to clusters: 640 16:14 - Stopping NMC 16:14 - Found 0 PPS errors. 16:15 - Checking high voltages... 16:15 - Starting task "Check HV" 16:15 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_6pe.NMC.xml 16:15 - Done 16:15 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1276.12 V. 16:15 - Maximum difference between reference and actual voltage is 1.21 V 16:15 - Checking status of HVPA module in 12 drawer(s)... 16:15 - Checking status of HVPA channels in 12 drawer(s)... 16:15 - HV is stabilized in all channels. 16:15 - Finished task "Check HV" 16:24 - Resetting NMC 16:25 - Starting task "Configure NMC" 16:25 - Configuring modules with configuration /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_5pe.NMC.xml 16:25 - NMC is in state NmcState.Configured and knows of 12 drawer(s) 16:25 - Found 0 PPS errors. 16:25 - Finished task "Configure NMC" 16:27 - Starting NMC 16:27 - Clearing PPS error counters 16:27 - Configuring TIB... 16:27 - Setting TIB forced mode to False 16:27 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 16:27 - Status: TibState.PpsStopped 16:27 - Alarms: AlarmVector.NoAlarm 16:27 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 16:27 - Setting TIB trigger mode to 0x1 = TriggerMask.Mono 16:27 - Writing 1 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 16:27 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 16:27 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 16:27 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 16:27 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 16:27 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 16:27 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 16:27 - Status: TibState.PpsStopped 16:27 - Alarms: AlarmVector.NoAlarm 16:28 - Closing TIB connection to camera server 16:28 - Connecting TIB to camera server at 10.10.0.251:222 16:28 - Starting TIB... 16:28 - Status: TibState.PpsStopped 16:28 - Alarms: AlarmVector.NoAlarm 16:28 - Resetting run 16:28 - Wait for UCTS external trigger before enabling trigger... 16:28 - Status: TibState.Standby 16:28 - Alarms: AlarmVector.NoAlarm 16:28 - Status: TibState.Standby 16:28 - Alarms: AlarmVector.NoAlarm 16:28 - Status: TibState.Armed 16:28 - Alarms: AlarmVector.NoAlarm 16:28 - Starting TIB triggers... 16:28 - Enabling trigger 16:28 - Status: TibState.Running 16:28 - Alarms: AlarmVector.NoAlarm 16:29 - Stopping TIB... 16:29 - Status: TibState.Running 16:29 - Alarms: AlarmVector.NoAlarm 16:29 - Disabling trigger 16:29 - Disabling PPS 16:29 - Status: TibState.PpsStopped 16:29 - Alarms: AlarmVector.NoAlarm 16:29 - Closing TIB connection to camera server 16:30 - Status: TibState.PpsStopped 16:30 - Alarms: AlarmVector.NoAlarm 16:30 - Run duration: 0:01:35 16:30 - Local camera triggers: 0 16:30 - Slow control triggers: 0 16:30 - Single photo-electron triggers: 0 16:30 - Calibration triggers: 0 16:30 - Software triggers from UCTS: 0 16:30 - Auto-pedestal triggers: 616777 16:30 - Collected input triggers: 13952 16:30 - Busy triggers: 14 16:30 - Non-busy triggers sent to UCTS: 13939 16:30 - Camera event triggers sent to clusters: 13939 16:31 - Stopping NMC 16:31 - Found 0 PPS errors. 16:31 - Checking high voltages... 16:31 - Starting task "Check HV" 16:31 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_5pe.NMC.xml 16:31 - Done 16:31 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1276.12 V. 16:31 - Maximum difference between reference and actual voltage is 1.82 V 16:31 - Checking status of HVPA module in 12 drawer(s)... 16:31 - Checking status of HVPA channels in 12 drawer(s)... 16:31 - HV is stabilized in all channels. 16:31 - Finished task "Check HV" 16:31 - Checking high voltages... 16:31 - Starting task "Check HV" 16:31 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_5pe.NMC.xml 16:31 - Done 16:31 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1276.12 V. 16:31 - Maximum difference between reference and actual voltage is 1.66 V 16:31 - Checking status of HVPA module in 12 drawer(s)... 16:31 - Checking status of HVPA channels in 12 drawer(s)... 16:31 - HV is stabilized in all channels. 16:31 - Finished task "Check HV" 16:44 - Resetting NMC 16:45 - Starting task "Configure NMC" 16:45 - Configuring modules with configuration /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_4pe.NMC.xml 16:45 - NMC is in state NmcState.Configured and knows of 12 drawer(s) 16:45 - Found 0 PPS errors. 16:45 - Finished task "Configure NMC" 16:45 - Checking high voltages... 16:45 - Starting task "Check HV" 16:45 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_4pe.NMC.xml 16:45 - Reference voltage of channel 5 in drawer #3: expected 1228.53, read 1231.75 16:45 - Done 16:45 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1276.12 V. 16:45 - Maximum difference between reference and actual voltage is 1.22 V 16:45 - Checking status of HVPA module in 12 drawer(s)... 16:45 - Checking status of HVPA channels in 12 drawer(s)... 16:45 - HV is stabilized in all channels. 16:45 - Finished task "Check HV" 16:45 - Checking high voltages... 16:45 - Starting task "Check HV" 16:45 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_4pe.NMC.xml 16:45 - Reference voltage of channel 5 in drawer #3: expected 1228.53, read 1231.75 16:45 - Done 16:46 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1276.73 V. 16:46 - Maximum difference between reference and actual voltage is 1.21 V 16:46 - Checking status of HVPA module in 12 drawer(s)... 16:46 - Checking status of HVPA channels in 12 drawer(s)... 16:46 - HV is stabilized in all channels. 16:46 - Finished task "Check HV" 16:46 - Checking high voltages... 16:46 - Starting task "Check HV" 16:46 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_4pe.NMC.xml 16:46 - Reference voltage of channel 5 in drawer #3: expected 1228.53, read 1231.75 16:46 - Done 16:46 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1276.73 V. 16:46 - Maximum difference between reference and actual voltage is 1.21 V 16:46 - Checking status of HVPA module in 12 drawer(s)... 16:46 - Checking status of HVPA channels in 12 drawer(s)... 16:46 - HV is stabilized in all channels. 16:46 - Finished task "Check HV" 16:46 - Resetting NMC 16:46 - Starting task "Configure NMC" 16:46 - Configuring modules with configuration /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_4pe.NMC.xml 16:46 - NMC is in state NmcState.Configured and knows of 12 drawer(s) 16:46 - Found 0 PPS errors. 16:46 - Finished task "Configure NMC" 16:46 - Checking high voltages... 16:46 - Starting task "Check HV" 16:46 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_4pe.NMC.xml 16:46 - Reference voltage of channel 2 in drawer #10: expected 1151.23, read 1144.95 16:46 - Done 16:46 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1276.12 V. 16:46 - Maximum difference between reference and actual voltage is 1.22 V 16:46 - Checking status of HVPA module in 12 drawer(s)... 16:46 - Checking status of HVPA channels in 12 drawer(s)... 16:46 - HV is stabilized in all channels. 16:46 - Finished task "Check HV" 16:46 - Resetting NMC 16:46 - Starting task "Configure NMC" 16:46 - Configuring modules with configuration /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_4pe.NMC.xml 16:47 - NMC is in state NmcState.Configured and knows of 12 drawer(s) 16:47 - Found 0 PPS errors. 16:47 - Finished task "Configure NMC" 16:47 - Checking high voltages... 16:47 - Starting task "Check HV" 16:47 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_4pe.NMC.xml 16:47 - Done 16:47 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1276.73 V. 16:47 - Maximum difference between reference and actual voltage is 1.21 V 16:47 - Checking status of HVPA module in 12 drawer(s)... 16:47 - Checking status of HVPA channels in 12 drawer(s)... 16:47 - HV is stabilized in all channels. 16:47 - Finished task "Check HV" 16:47 - Starting NMC 16:47 - Clearing PPS error counters 16:47 - Configuring TIB... 16:47 - Setting TIB forced mode to False 16:47 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 16:47 - Status: TibState.PpsStopped 16:47 - Alarms: AlarmVector.NoAlarm 16:47 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 16:47 - Setting TIB trigger mode to 0x1 = TriggerMask.Mono 16:47 - Writing 1 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 16:47 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 16:47 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 16:47 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 16:47 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 16:47 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 16:47 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 16:47 - Status: TibState.PpsStopped 16:47 - Alarms: AlarmVector.NoAlarm 16:47 - Closing TIB connection to camera server 16:47 - Connecting TIB to camera server at 10.10.0.251:222 16:47 - Starting TIB... 16:47 - Status: TibState.PpsStopped 16:47 - Alarms: AlarmVector.NoAlarm 16:47 - Resetting run 16:47 - Wait for UCTS external trigger before enabling trigger... 16:47 - Status: TibState.Standby 16:47 - Alarms: AlarmVector.NoAlarm 16:47 - Status: TibState.Standby 16:47 - Alarms: AlarmVector.NoAlarm 16:47 - Status: TibState.CoutingPps 16:47 - Alarms: AlarmVector.NoAlarm 16:48 - Starting TIB triggers... 16:48 - Enabling trigger 16:48 - Status: TibState.Running 16:48 - Alarms: AlarmVector.NoAlarm 16:48 - Stopping TIB... 16:48 - Status: TibState.Running 16:48 - Alarms: AlarmVector.NoAlarm 16:48 - Disabling trigger 16:48 - Disabling PPS 16:48 - Status: TibState.PpsStopped 16:48 - Alarms: AlarmVector.NoAlarm 16:48 - Closing TIB connection to camera server 16:48 - Status: TibState.PpsStopped 16:48 - Alarms: AlarmVector.NoAlarm 16:48 - Run duration: 0:00:36 16:48 - Local camera triggers: 0 16:48 - Slow control triggers: 0 16:48 - Single photo-electron triggers: 0 16:48 - Calibration triggers: 0 16:48 - Software triggers from UCTS: 0 16:48 - Auto-pedestal triggers: 233041 16:48 - Collected input triggers: 108476 16:48 - Busy triggers: 3050 16:48 - Non-busy triggers sent to UCTS: 105428 16:48 - Camera event triggers sent to clusters: 105428 16:49 - Stopping NMC 16:49 - Found 0 PPS errors. 16:49 - Checking high voltages... 16:49 - Starting task "Check HV" 16:49 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_4pe.NMC.xml 16:49 - Done 16:49 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.07 V and 1277.34 V. 16:49 - Maximum difference between reference and actual voltage is 1.82 V 16:49 - Checking status of HVPA module in 12 drawer(s)... 16:49 - Checking status of HVPA channels in 12 drawer(s)... 16:49 - HV is stabilized in all channels. 16:49 - Finished task "Check HV"