14:45 - Status: TibState.PpsStopped 14:45 - Alarms: AlarmVector.NoAlarm 14:45 - External delay: 0.0 ns 14:45 - Trigger mask: 0x1 = TriggerMask.Mono 14:45 - Input mask: 0x0 14:45 - Disable BUSY: False 14:45 - Extra BUSY Delay: 0.0 14:45 - Temperature: 37.0 14:45 - Stopping NMC 14:45 - Found 0 PPS errors. 14:46 - Checking high voltages... 14:46 - Starting task "Check HV" 14:46 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_2.0pe.NMC.xml 14:46 - Done 14:46 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 969.29 V and 1276.73 V. 14:46 - Maximum difference between reference and actual voltage is 1.21 V 14:46 - Checking status of HVPA module in 12 drawer(s)... 14:46 - Checking status of HVPA channels in 12 drawer(s)... 14:46 - HV is stabilized in all channels. 14:46 - Finished task "Check HV" 14:46 - Starting NMC 14:46 - Clearing PPS error counters 14:48 - Configuring TIB... 14:48 - Setting TIB forced mode to False 14:48 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 14:48 - Status: TibState.PpsStopped 14:48 - Alarms: AlarmVector.NoAlarm 14:48 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 14:48 - Setting TIB trigger mode to 0x1 = TriggerMask.Mono 14:48 - Writing 1 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 14:48 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 14:48 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 14:48 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 14:48 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 14:48 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 14:48 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 14:48 - Status: TibState.PpsStopped 14:48 - Alarms: AlarmVector.NoAlarm 14:48 - Closing TIB connection to camera server 14:48 - Connecting TIB to camera server at 10.10.0.251:222 14:48 - Starting TIB... 14:48 - Status: TibState.PpsStopped 14:48 - Alarms: AlarmVector.NoAlarm 14:48 - Resetting run 14:48 - Wait for UCTS external trigger before enabling trigger... 14:48 - Status: TibState.Standby 14:48 - Alarms: AlarmVector.NoAlarm 14:48 - Status: TibState.Standby 14:48 - Alarms: AlarmVector.NoAlarm 14:48 - Status: TibState.CoutingPps 14:48 - Alarms: AlarmVector.NoAlarm 14:49 - Starting TIB triggers... 14:49 - Enabling trigger 14:49 - Status: TibState.Running 14:49 - Alarms: AlarmVector.NoAlarm 14:49 - Status: TibState.Running ConnectionStatus: True 14:49 - Alarms: AlarmVector.NoAlarm 14:49 - Temperature: 37.0 14:49 - Local camera rate: 0.0 Hz 14:49 - Stereo trigger rate: 0.0 Hz 14:49 - SPE trigger rate: 0.0 Hz 14:49 - Calibration trigger rate: 0.0 Hz 14:49 - Software trigger rate: 0.0 Hz 14:49 - Auto-pedestal trigger rate: 6408.0 Hz 14:49 - Collected trigger rate: 56466.0 Hz 14:49 - Busy rate: 15650.0 Hz 14:49 - Camera trigger rate: 40846.0 Hz 14:49 - Stopping TIB... 14:49 - Status: TibState.Running 14:49 - Alarms: AlarmVector.NoAlarm 14:49 - Disabling trigger 14:49 - Disabling PPS 14:49 - Status: TibState.PpsStopped 14:49 - Alarms: AlarmVector.NoAlarm 14:49 - Closing TIB connection to camera server 14:51 - Stopping NMC 14:51 - Found 0 PPS errors. 14:51 - Checking high voltages... 14:51 - Starting task "Check HV" 14:51 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_2.0pe.NMC.xml 14:51 - Done 14:51 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1276.73 V. 14:51 - Maximum difference between reference and actual voltage is 1.21 V 14:51 - Checking status of HVPA module in 12 drawer(s)... 14:51 - Checking status of HVPA channels in 12 drawer(s)... 14:51 - HV is stabilized in all channels. 14:51 - Finished task "Check HV"