14:22 - Resetting NMC 14:22 - Starting task "Configure NMC" 14:22 - Configuring modules with configuration /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_3.5pe.NMC.xml 14:22 - NMC is in state NmcState.Configured and knows of 12 drawer(s) 14:22 - Found 0 PPS errors. 14:22 - Finished task "Configure NMC" 14:22 - Checking high voltages... 14:22 - Starting task "Check HV" 14:22 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_3.5pe.NMC.xml 14:22 - Done 14:22 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.34 V. 14:22 - Maximum difference between reference and actual voltage is 1.66 V 14:22 - Checking status of HVPA module in 12 drawer(s)... 14:22 - Checking status of HVPA channels in 12 drawer(s)... 14:22 - HV is stabilized in all channels. 14:22 - Finished task "Check HV" 14:22 - Starting NMC 14:22 - Clearing PPS error counters 14:22 - Configuring TIB... 14:22 - Setting TIB forced mode to False 14:22 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 14:22 - Status: TibState.PpsStopped 14:22 - Alarms: AlarmVector.NoAlarm 14:22 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 14:22 - Setting TIB trigger mode to 0x1 = TriggerMask.Mono 14:22 - Writing 1 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 14:22 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 14:22 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 14:22 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 14:22 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 14:22 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 14:22 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 14:22 - Status: TibState.PpsStopped 14:22 - Alarms: AlarmVector.NoAlarm 14:22 - Closing TIB connection to camera server 14:22 - Connecting TIB to camera server at 10.10.0.251:222 14:22 - Starting TIB... 14:22 - Status: TibState.PpsStopped 14:22 - Alarms: AlarmVector.NoAlarm 14:22 - Resetting run 14:22 - Wait for UCTS external trigger before enabling trigger... 14:22 - Status: TibState.Standby 14:22 - Alarms: AlarmVector.NoAlarm 14:22 - Status: TibState.Standby 14:22 - Alarms: AlarmVector.NoAlarm 14:23 - Status: TibState.CoutingPps 14:23 - Alarms: AlarmVector.NoAlarm 14:23 - Starting TIB triggers... 14:23 - Enabling trigger 14:23 - Status: TibState.Running 14:23 - Alarms: AlarmVector.NoAlarm 14:25 - Stopping TIB... 14:25 - Status: TibState.Running 14:25 - Alarms: AlarmVector.NoAlarm 14:25 - Disabling trigger 14:25 - Status: TibState.RunStopped 14:25 - Alarms: AlarmVector.NoAlarm 14:25 - Disabling PPS 14:25 - Status: TibState.PpsStopped 14:25 - Alarms: AlarmVector.NoAlarm 14:25 - Closing TIB connection to camera server 14:25 - Status: TibState.PpsStopped 14:25 - Alarms: AlarmVector.NoAlarm 14:25 - Run duration: 0:02:41 14:25 - Local camera triggers: 0 14:25 - Slow control triggers: 0 14:25 - Single photo-electron triggers: 0 14:25 - Calibration triggers: 0 14:25 - Software triggers from UCTS: 0 14:25 - Auto-pedestal triggers: 1049276 14:25 - Collected input triggers: 14336 14:25 - Busy triggers: 7 14:25 - Non-busy triggers sent to UCTS: 14329 14:25 - Camera event triggers sent to clusters: 14329 14:26 - Stopping NMC 14:26 - Found 0 PPS errors. 14:26 - Checking high voltages... 14:26 - Starting task "Check HV" 14:26 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_3.5pe.NMC.xml 14:26 - Done 14:26 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1276.73 V. 14:26 - Maximum difference between reference and actual voltage is 1.21 V 14:26 - Checking status of HVPA module in 12 drawer(s)... 14:26 - Checking status of HVPA channels in 12 drawer(s)... 14:26 - HV is stabilized in all channels. 14:26 - Finished task "Check HV"