13:39 - Resetting NMC 13:39 - Starting task "Configure NMC" 13:39 - Configuring modules with configuration /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_5pe.NMC.xml 13:39 - NMC is in state NmcState.Configured and knows of 12 drawer(s) 13:39 - Found 0 PPS errors. 13:39 - Finished task "Configure NMC" 13:39 - Checking high voltages... 13:39 - Starting task "Check HV" 13:39 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_5pe.NMC.xml 13:39 - Reference voltage of channel 2 in drawer #3: expected 1097.14, read 1101.67 13:39 - Reference voltage of channel 6 in drawer #14: expected 1169.71, read 1175.09 13:39 - Done 13:39 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.34 V. 13:39 - Maximum difference between reference and actual voltage is 1.66 V 13:39 - Checking status of HVPA module in 12 drawer(s)... 13:39 - Checking status of HVPA channels in 12 drawer(s)... 13:39 - HV is stabilized in all channels. 13:39 - Finished task "Check HV" 13:39 - Starting NMC 13:39 - Clearing PPS error counters 13:39 - Configuring TIB... 13:39 - Setting TIB forced mode to False 13:39 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 13:39 - Status: TibState.PpsStopped 13:39 - Alarms: AlarmVector.NoAlarm 13:39 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 13:39 - Setting TIB trigger mode to 0x1 = TriggerMask.Mono 13:39 - Writing 1 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 13:39 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 13:39 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 13:39 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 13:39 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 13:39 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 13:39 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 13:39 - Status: TibState.PpsStopped 13:39 - Alarms: AlarmVector.NoAlarm 13:39 - Closing TIB connection to camera server 13:39 - Connecting TIB to camera server at 10.10.0.251:222 13:39 - Starting TIB... 13:39 - Status: TibState.PpsStopped 13:39 - Alarms: AlarmVector.NoAlarm 13:39 - Resetting run 13:39 - Wait for UCTS external trigger before enabling trigger... 13:39 - Status: TibState.Standby 13:39 - Alarms: AlarmVector.NoAlarm 13:39 - Status: TibState.Standby 13:39 - Alarms: AlarmVector.NoAlarm 13:39 - Status: TibState.CoutingPps 13:39 - Alarms: AlarmVector.NoAlarm 13:39 - Starting TIB triggers... 13:39 - Enabling trigger 13:39 - Status: TibState.Running 13:39 - Alarms: AlarmVector.NoAlarm 14:00 - Stopping TIB... 14:00 - Status: TibState.Running 14:00 - Alarms: AlarmVector.NoAlarm 14:00 - Disabling trigger 14:00 - Status: TibState.RunStopped 14:00 - Alarms: AlarmVector.NoAlarm 14:00 - Disabling PPS 14:00 - Status: TibState.PpsStopped 14:00 - Alarms: AlarmVector.NoAlarm 14:00 - Closing TIB connection to camera server 14:00 - Status: TibState.PpsStopped 14:00 - Alarms: AlarmVector.NoAlarm 14:00 - Run duration: 0:20:36 14:00 - Local camera triggers: 0 14:00 - Slow control triggers: 0 14:00 - Single photo-electron triggers: 0 14:00 - Calibration triggers: 0 14:00 - Software triggers from UCTS: 0 14:00 - Auto-pedestal triggers: 8042876 14:00 - Collected input triggers: 223 14:00 - Busy triggers: 0 14:00 - Non-busy triggers sent to UCTS: 223 14:00 - Camera event triggers sent to clusters: 223 14:00 - Stopping NMC 14:00 - Found 0 PPS errors. 14:00 - Checking high voltages... 14:00 - Starting task "Check HV" 14:00 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_5pe.NMC.xml 14:00 - Reference voltage of channel 2 in drawer #3: expected 1097.14, read 1101.67 14:00 - Reference voltage of channel 6 in drawer #14: expected 1169.71, read 1175.09 14:00 - Done 14:00 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.34 V. 14:00 - Maximum difference between reference and actual voltage is 1.66 V 14:00 - Checking status of HVPA module in 12 drawer(s)... 14:00 - Checking status of HVPA channels in 12 drawer(s)... 14:00 - HV is stabilized in all channels. 14:00 - Finished task "Check HV"