12:35 - Checking high voltages... 12:35 - Starting task "Check HV" 12:35 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_7pe.NMC.xml 12:35 - Done 12:35 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.34 V. 12:35 - Maximum difference between reference and actual voltage is 1.80 V 12:35 - Checking status of HVPA module in 12 drawer(s)... 12:35 - Checking status of HVPA channels in 12 drawer(s)... 12:35 - HV is stabilized in all channels. 12:35 - Finished task "Check HV" 12:36 - Starting NMC 12:36 - Clearing PPS error counters 12:36 - Configuring TIB... 12:36 - Setting TIB forced mode to False 12:36 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 12:36 - Status: TibState.PpsStopped 12:36 - Alarms: AlarmVector.NoAlarm 12:36 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 12:36 - Setting TIB trigger mode to 0x1 = TriggerMask.Mono 12:36 - Writing 1 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 12:36 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 12:36 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 12:36 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 12:36 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 12:36 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 12:36 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 12:36 - Status: TibState.PpsStopped 12:36 - Alarms: AlarmVector.NoAlarm 12:36 - Closing TIB connection to camera server 12:36 - Connecting TIB to camera server at 10.10.0.251:222 12:36 - Starting TIB... 12:36 - Status: TibState.PpsStopped 12:36 - Alarms: AlarmVector.NoAlarm 12:36 - Resetting run 12:36 - Wait for UCTS external trigger before enabling trigger... 12:36 - Status: TibState.Standby 12:36 - Alarms: AlarmVector.NoAlarm 12:36 - Status: TibState.Standby 12:36 - Alarms: AlarmVector.NoAlarm 12:36 - Status: TibState.CoutingPps 12:36 - Alarms: AlarmVector.NoAlarm 12:36 - Starting TIB triggers... 12:36 - Enabling trigger 12:36 - Status: TibState.Running 12:36 - Alarms: AlarmVector.NoAlarm 13:03 - Stopping TIB... 13:03 - Status: TibState.Running 13:03 - Alarms: AlarmVector.NoAlarm 13:03 - Disabling trigger 13:03 - Status: TibState.RunStopped 13:03 - Alarms: AlarmVector.NoAlarm 13:03 - Disabling PPS 13:03 - Status: TibState.PpsStopped 13:03 - Alarms: AlarmVector.NoAlarm 13:03 - Closing TIB connection to camera server 13:03 - Status: TibState.PpsStopped 13:03 - Alarms: AlarmVector.NoAlarm 13:03 - Run duration: 0:26:56 13:03 - Local camera triggers: 0 13:03 - Slow control triggers: 0 13:03 - Single photo-electron triggers: 0 13:03 - Calibration triggers: 0 13:03 - Software triggers from UCTS: 0 13:03 - Auto-pedestal triggers: 10522446 13:03 - Collected input triggers: 22 13:03 - Busy triggers: 0 13:03 - Non-busy triggers sent to UCTS: 22 13:03 - Camera event triggers sent to clusters: 22 13:03 - Stopping NMC 13:03 - Found 0 PPS errors. 13:03 - Checking high voltages... 13:03 - Starting task "Check HV" 13:03 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180314/config_1module_3NN_7pe.NMC.xml 13:03 - Done 13:03 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.34 V. 13:03 - Maximum difference between reference and actual voltage is 1.60 V 13:03 - Checking status of HVPA module in 12 drawer(s)... 13:03 - Checking status of HVPA channels in 12 drawer(s)... 13:03 - HV is stabilized in all channels. 13:03 - Finished task "Check HV"