17:56 - ECC is in state EccState.Ready with status EccStatus.NoError 17:56 - ECC temperature sensors: T1= 34.3, T2= 24.6, T3= 23.9, T4= 24.1 deg C 17:56 - 24 V power supply no. 1 is enabled with a current of 9.680 A. 17:56 - Stopping NMC 17:56 - Found 0 PPS errors. 17:56 - Checking high voltages... 17:56 - Starting task "Check HV" 17:56 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180307/config_12modules_SPE.NMC.xml 17:56 - Done 17:57 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.34 V. 17:57 - Maximum difference between reference and actual voltage is 2.27 V 17:57 - Checking status of HVPA module in 12 drawer(s)... 17:57 - Checking status of HVPA channels in 12 drawer(s)... 17:57 - HV is stabilized in all channels. 17:57 - Finished task "Check HV" 17:57 - Configuring calibration box... 17:57 - Configuring calibration box with leds=0x0 voltage=10.00 frequency=10000.0/1 central_current=0 duration=1 width=True lemo_out=True fiber1_out=True fiber2_out=False lemo_in=False enabled=0.0 17:57 - Stopping flashes... 17:57 - Starting NMC 17:57 - Clearing PPS error counters 17:57 - Configuring TIB... 17:57 - Setting TIB forced mode to False 17:57 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 17:57 - Status: TibState.PpsStopped 17:57 - Alarms: AlarmVector.NoAlarm 17:57 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 17:57 - Setting TIB trigger mode to 0x48 = TriggerMask.SlowControl|SPhE 17:57 - Writing 72 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 17:57 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 17:57 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 17:57 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 17:57 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 17:57 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 17:57 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 17:57 - Status: TibState.PpsStopped 17:57 - Alarms: AlarmVector.NoAlarm 17:57 - Closing TIB connection to camera server 17:57 - Connecting TIB to camera server at 10.10.0.251:222 17:57 - Starting TIB... 17:57 - Status: TibState.PpsStopped 17:57 - Alarms: AlarmVector.NoAlarm 17:57 - Resetting run 17:57 - Wait for UCTS external trigger before enabling trigger... 17:57 - Status: TibState.Standby 17:57 - Alarms: AlarmVector.NoAlarm 17:57 - Status: TibState.Standby 17:57 - Alarms: AlarmVector.NoAlarm 17:57 - Status: TibState.CoutingPps 17:57 - Alarms: AlarmVector.NoAlarm 17:57 - Starting TIB triggers... 17:57 - Enabling trigger 17:57 - Status: TibState.Running 17:57 - Alarms: AlarmVector.NoAlarm 17:57 - Configuring calibration box... 17:57 - Configuring calibration box with leds=0x0 voltage=10.00 frequency=10000.0/1 central_current=0 duration=1 width=True lemo_out=True fiber1_out=True fiber2_out=True lemo_in=True enabled=0.0 17:57 - Status: TibState.Running ConnectionStatus: True 17:57 - Alarms: AlarmVector.NoAlarm 17:57 - Temperature: 36.9375 17:57 - Local camera rate: 0.0 Hz 17:57 - Stereo trigger rate: 0.0 Hz 17:57 - SPE trigger rate: 10298.0 Hz 17:57 - Calibration trigger rate: 0.0 Hz 17:57 - Software trigger rate: 0.0 Hz 17:57 - Auto-pedestal trigger rate: 6516.0 Hz 17:57 - Collected trigger rate: 10222.0 Hz 17:57 - Busy rate: 729.0 Hz 17:57 - Camera trigger rate: 9495.0 Hz 18:14 - Status: TibState.Running ConnectionStatus: True 18:14 - Alarms: AlarmVector.NoAlarm 18:14 - Temperature: 37.0625 18:14 - Local camera rate: 0.0 Hz 18:14 - Stereo trigger rate: 0.0 Hz 18:14 - SPE trigger rate: 10540.0 Hz 18:14 - Calibration trigger rate: 0.0 Hz 18:14 - Software trigger rate: 0.0 Hz 18:14 - Auto-pedestal trigger rate: 6364.0 Hz 18:14 - Collected trigger rate: 10469.0 Hz 18:14 - Busy rate: 784.0 Hz 18:14 - Camera trigger rate: 9685.0 Hz 08:12 - Stopping TIB... 08:12 - Status: TibState.Running 08:12 - Alarms: AlarmVector.NoAlarm 08:12 - Disabling trigger 08:12 - Status: TibState.RunStopped 08:12 - Alarms: AlarmVector.NoAlarm 08:12 - Disabling PPS 08:12 - Status: TibState.PpsStopped 08:12 - Alarms: AlarmVector.NoAlarm 08:12 - Closing TIB connection to camera server 08:12 - Status: TibState.PpsStopped 08:12 - Alarms: AlarmVector.NoAlarm 08:12 - Run duration: 14:14:51 08:12 - Local camera triggers: 0 08:12 - Slow control triggers: 0 08:12 - Single photo-electron triggers: 525176291 08:12 - Calibration triggers: 0 08:12 - Software triggers from UCTS: 0 08:12 - Auto-pedestal triggers: 333922674 08:12 - Collected input triggers: 521636006 08:12 - Busy triggers: 36445907 08:12 - Non-busy triggers sent to UCTS: 485245756 08:12 - Camera event triggers sent to clusters: 485245753 08:12 - Configuring calibration box... 08:12 - Configuring calibration box with leds=0x0 voltage=10.00 frequency=10000.0/1 central_current=0 duration=1 width=True lemo_out=True fiber1_out=True fiber2_out=False lemo_in=False enabled=0.0 08:12 - Stopping NMC 08:12 - Found 0 PPS errors. 08:12 - Checking high voltages... 08:12 - Starting task "Check HV" 08:12 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180307/config_12modules_SPE.NMC.xml 08:12 - Done 08:12 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.95 V. 08:12 - Maximum difference between reference and actual voltage is 2.27 V 08:12 - Checking status of HVPA module in 12 drawer(s)... 08:12 - Checking status of HVPA channels in 12 drawer(s)... 08:12 - HV is stabilized in all channels. 08:12 - Finished task "Check HV"