17:37 - ECC is in state EccState.Ready with status EccStatus.NoError 17:37 - ECC temperature sensors: T1= 34.1, T2= 24.4, T3= 23.7, T4= 23.9 deg C 17:37 - 24 V power supply no. 1 is enabled with a current of 9.710 A. 17:37 - Checking high voltages... 17:37 - Starting task "Check HV" 17:37 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180307/config_12modules_SPE.NMC.xml 17:37 - Done 17:37 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.34 V. 17:38 - Maximum difference between reference and actual voltage is 2.44 V 17:38 - Checking status of HVPA module in 12 drawer(s)... 17:38 - Checking status of HVPA channels in 12 drawer(s)... 17:38 - HV is stabilized in all channels. 17:38 - Finished task "Check HV" 17:38 - Starting NMC 17:38 - Clearing PPS error counters 17:38 - Configuring TIB... 17:38 - Setting TIB forced mode to False 17:38 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 17:38 - Status: TibState.PpsStopped 17:38 - Alarms: AlarmVector.NoAlarm 17:38 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 17:38 - Setting TIB trigger mode to 0x48 = TriggerMask.SlowControl|SPhE 17:38 - Writing 72 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 17:38 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 17:38 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 17:38 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 17:38 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 17:38 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 17:38 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 17:38 - Status: TibState.PpsStopped 17:38 - Alarms: AlarmVector.NoAlarm 17:38 - Closing TIB connection to camera server 17:38 - Connecting TIB to camera server at 10.10.0.251:222 17:38 - Starting TIB... 17:38 - Status: TibState.PpsStopped 17:38 - Alarms: AlarmVector.NoAlarm 17:38 - Resetting run 17:38 - Wait for UCTS external trigger before enabling trigger... 17:38 - Status: TibState.Standby 17:38 - Alarms: AlarmVector.NoAlarm 17:38 - Status: TibState.Standby 17:38 - Alarms: AlarmVector.NoAlarm 17:38 - Status: TibState.CoutingPps 17:38 - Alarms: AlarmVector.NoAlarm 17:38 - Starting TIB triggers... 17:38 - Enabling trigger 17:38 - Status: TibState.Running 17:38 - Alarms: AlarmVector.NoAlarm 17:40 - Configuring calibration box... 17:40 - Configuring calibration box with leds=0x358 voltage=9.25 frequency=1000.0/1 central_current=100 duration=1 width=True lemo_out=True fiber1_out=True fiber2_out=True lemo_in=True enabled=0.0 17:40 - Configuring calibration box... 17:40 - Configuring calibration box with leds=0x358 voltage=9.25 frequency=1000.0/1 central_current=100 duration=1 width=True lemo_out=True fiber1_out=True fiber2_out=False lemo_in=False enabled=0.0 17:41 - Stopping TIB... 17:41 - Status: TibState.Running 17:41 - Alarms: AlarmVector.NoAlarm 17:41 - Disabling trigger 17:41 - Status: TibState.RunStopped 17:41 - Alarms: AlarmVector.NoAlarm 17:41 - Disabling PPS 17:41 - Status: TibState.PpsStopped 17:41 - Alarms: AlarmVector.NoAlarm 17:41 - Closing TIB connection to camera server 17:41 - Status: TibState.PpsStopped 17:41 - Alarms: AlarmVector.NoAlarm 17:41 - Run duration: 0:02:54 17:41 - Local camera triggers: 0 17:41 - Slow control triggers: 0 17:41 - Single photo-electron triggers: 123742 17:41 - Calibration triggers: 0 17:41 - Software triggers from UCTS: 0 17:41 - Auto-pedestal triggers: 1129668 17:41 - Collected input triggers: 122902 17:41 - Busy triggers: 8842 17:41 - Non-busy triggers sent to UCTS: 114068 17:41 - Camera event triggers sent to clusters: 114068 17:41 - Stopping NMC 17:41 - Found 0 PPS errors. 17:41 - Checking high voltages... 17:41 - Starting task "Check HV" 17:41 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180307/config_12modules_SPE.NMC.xml 17:41 - Done 17:41 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.95 V. 17:41 - Maximum difference between reference and actual voltage is 1.83 V 17:41 - Checking status of HVPA module in 12 drawer(s)... 17:41 - Checking status of HVPA channels in 12 drawer(s)... 17:41 - HV is stabilized in all channels. 17:41 - Finished task "Check HV"