16:05 - ECC is in state EccState.Ready with status EccStatus.NoError 16:05 - ECC temperature sensors: T1= 33.0, T2= 24.2, T3= 23.6, T4= 23.8 deg C 16:05 - 24 V power supply no. 1 is enabled with a current of 9.720 A. 16:05 - Checking high voltages... 16:05 - Starting task "Check HV" 16:05 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180307/config_12modules_SPE.NMC.xml 16:05 - Done 16:05 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 969.29 V and 1277.34 V. 16:05 - Maximum difference between reference and actual voltage is 1.83 V 16:05 - Checking status of HVPA module in 12 drawer(s)... 16:05 - Checking status of HVPA channels in 12 drawer(s)... 16:05 - HV is stabilized in all channels. 16:05 - Finished task "Check HV" 16:05 - Starting NMC 16:05 - Clearing PPS error counters 16:05 - Configuring TIB... 16:05 - Setting TIB forced mode to False 16:05 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 16:05 - Status: TibState.RunStopped 16:05 - Alarms: AlarmVector.NoAlarm 16:05 - Disabling PPS 16:05 - Status: TibState.PpsStopped 16:05 - Alarms: AlarmVector.NoAlarm 16:05 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 16:05 - Setting TIB trigger mode to 0x48 = TriggerMask.SlowControl|SPhE 16:05 - Writing 72 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 16:05 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 16:05 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 16:05 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 16:05 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 16:05 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 16:05 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 16:05 - Status: TibState.PpsStopped 16:05 - Alarms: AlarmVector.NoAlarm 16:05 - Closing TIB connection to camera server 16:05 - Connecting TIB to camera server at 10.10.0.251:222 16:05 - Starting TIB... 16:05 - Status: TibState.PpsStopped 16:05 - Alarms: AlarmVector.NoAlarm 16:05 - Resetting run 16:05 - Wait for UCTS external trigger before enabling trigger... 16:05 - Status: TibState.Standby 16:05 - Alarms: AlarmVector.NoAlarm 16:05 - Status: TibState.Standby 16:05 - Alarms: AlarmVector.NoAlarm 16:05 - Status: TibState.CoutingPps 16:05 - Alarms: AlarmVector.NoAlarm 16:05 - Starting TIB triggers... 16:05 - Enabling trigger 16:05 - Status: TibState.Running 16:05 - Alarms: AlarmVector.NoAlarm 16:05 - Configuring calibration box... 16:05 - Configuring calibration box with leds=0x0 voltage=10.00 frequency=1000.0/1 central_current=250 duration=1 width=True lemo_out=True fiber1_out=True fiber2_out=False lemo_in=False enabled=0.0 16:06 - Starting flashes... 16:06 - Stopping flashes... 16:06 - Stopping TIB... 16:06 - Status: TibState.Running 16:06 - Alarms: AlarmVector.NoAlarm 16:06 - Disabling trigger 16:06 - Status: TibState.RunStopped 16:06 - Alarms: AlarmVector.NoAlarm 16:06 - Disabling PPS 16:06 - Status: TibState.PpsStopped 16:06 - Alarms: AlarmVector.NoAlarm 16:06 - Closing TIB connection to camera server 16:07 - Stopping NMC 16:07 - Found 0 PPS errors. 16:07 - Status: TibState.PpsStopped 16:07 - Alarms: AlarmVector.NoAlarm 16:07 - Run duration: 0:01:29 16:07 - Local camera triggers: 0 16:07 - Slow control triggers: 0 16:07 - Single photo-electron triggers: 24923 16:07 - Calibration triggers: 0 16:07 - Software triggers from UCTS: 0 16:07 - Auto-pedestal triggers: 576002 16:07 - Collected input triggers: 24923 16:07 - Busy triggers: 0 16:07 - Non-busy triggers sent to UCTS: 24923 16:07 - Camera event triggers sent to clusters: 24923 16:07 - Checking high voltages... 16:07 - Starting task "Check HV" 16:07 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180307/config_12modules_SPE.NMC.xml 16:07 - Done 16:07 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1276.73 V. 16:07 - Maximum difference between reference and actual voltage is 1.83 V 16:07 - Checking status of HVPA module in 12 drawer(s)... 16:07 - Checking status of HVPA channels in 12 drawer(s)... 16:07 - HV is stabilized in all channels. 16:07 - Finished task "Check HV"