13:31 - ECC is in state EccState.Ready with status EccStatus.NoError 13:31 - ECC temperature sensors: T1= 33.8, T2= 23.9, T3= 23.4, T4= 23.8 deg C 13:31 - 24 V power supply no. 1 is enabled with a current of 9.770 A. 13:31 - Checking high voltages... 13:31 - Starting task "Check HV" 13:31 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180213/config_12modules_SPE.NMC.xml 13:31 - Done 13:31 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1276.73 V. 13:31 - Maximum difference between reference and actual voltage is 1.66 V 13:31 - Checking status of HVPA module in 12 drawer(s)... 13:31 - Checking status of HVPA channels in 12 drawer(s)... 13:31 - HV is stabilized in all channels. 13:31 - Finished task "Check HV" 13:32 - Starting NMC 13:32 - Clearing PPS error counters 13:32 - Configuring TIB... 13:32 - Setting TIB forced mode to False 13:32 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 13:32 - Status: TibState.PpsStopped 13:32 - Alarms: AlarmVector.NoAlarm 13:32 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 13:32 - Setting TIB trigger mode to 0x48 = TriggerMask.SlowControl|SPhE 13:32 - Writing 72 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 13:32 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 13:32 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 13:32 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 13:32 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 13:32 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 13:32 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 13:32 - Status: TibState.PpsStopped 13:32 - Alarms: AlarmVector.NoAlarm 13:32 - Closing TIB connection to camera server 13:32 - Connecting TIB to camera server at 10.10.0.251:222 13:32 - Starting TIB... 13:32 - Status: TibState.PpsStopped 13:32 - Alarms: AlarmVector.NoAlarm 13:32 - Resetting run 13:32 - Wait for UCTS external trigger before enabling trigger... 13:32 - Status: TibState.Standby 13:32 - Alarms: AlarmVector.NoAlarm 13:32 - Status: TibState.Standby 13:32 - Alarms: AlarmVector.NoAlarm 13:32 - Status: TibState.CoutingPps 13:32 - Alarms: AlarmVector.NoAlarm 13:32 - Starting TIB triggers... 13:32 - Enabling trigger 13:32 - Status: TibState.Running 13:32 - Alarms: AlarmVector.NoAlarm INFO Scanning voltage of the calibration box from 8.000000 V to 16.010000 V INFO Setting LED mask to 0x0 INFO Configuring calibration box with leds=0x0 voltage=8.00 frequency=300.0/3 duration=0 width=1 lemo_out=True fiber1_out=True fiber2_out=False enabled=False INFO Starting flashes... INFO Stopping flashes... INFO Setting LED mask to 0x40 INFO Setting voltage to 8.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 8.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 8.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 8.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 9.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 9.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 9.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 9.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 10.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 10.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 10.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 10.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 11.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 11.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 11.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 11.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 12.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 12.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 12.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 12.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 13.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 13.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 13.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 13.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 14.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 14.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 14.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 14.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 15.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 15.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 15.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 15.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 16.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Scan took 0:10:14.575988 13:48 - Stopping TIB... 13:48 - Status: TibState.Running 13:48 - Alarms: AlarmVector.NoAlarm 13:48 - Disabling trigger 13:48 - Status: TibState.RunStopped 13:48 - Alarms: AlarmVector.NoAlarm 13:48 - Disabling PPS 13:49 - Status: TibState.PpsStopped 13:49 - Alarms: AlarmVector.NoAlarm 13:49 - Closing TIB connection to camera server 13:49 - Status: TibState.PpsStopped 13:49 - Alarms: AlarmVector.NoAlarm 13:49 - Run duration: 0:16:50 13:49 - Local camera triggers: 0 13:49 - Slow control triggers: 0 13:49 - Single photo-electron triggers: 37594 13:49 - Calibration triggers: 0 13:49 - Software triggers from UCTS: 0 13:49 - Auto-pedestal triggers: 6571324 13:49 - Collected input triggers: 37594 13:49 - Busy triggers: 0 13:49 - Non-busy triggers sent to UCTS: 37594 13:49 - Camera event triggers sent to clusters: 37594 13:49 - Stopping NMC 13:49 - Found 0 PPS errors. 13:49 - Checking high voltages... 13:49 - Starting task "Check HV" 13:49 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180213/config_12modules_SPE.NMC.xml 13:49 - Done 13:49 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.34 V. 13:49 - Maximum difference between reference and actual voltage is 1.82 V 13:49 - Checking status of HVPA module in 12 drawer(s)... 13:49 - Checking status of HVPA channels in 12 drawer(s)... 13:49 - HV is stabilized in all channels. 13:49 - Finished task "Check HV"