18:11 - ECC is in state EccState.Ready with status EccStatus.NoError 18:11 - ECC temperature sensors: T1= 34.0, T2= 24.4, T3= 23.5, T4= 23.7 deg C 18:11 - 24 V power supply no. 1 is enabled with a current of 9.560 A. 18:11 - Checking high voltages... 18:11 - Starting task "Check HV" 18:11 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180201/config_12modules_SPE.NMC.xml 18:11 - Reference voltage of channel 5 in drawer #4: expected 1225.58, read 1224.52 18:11 - Reference voltage of channel 2 in drawer #11: expected 1068.39, read 1066.10 18:11 - Done 18:11 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.34 V. 18:11 - Maximum difference between reference and actual voltage is 1.82 V 18:11 - Checking status of HVPA module in 12 drawer(s)... 18:11 - Checking status of HVPA channels in 12 drawer(s)... 18:11 - HV is stabilized in all channels. 18:11 - Finished task "Check HV" 18:11 - Resetting NMC 18:11 - Starting task "Configure NMC" 18:11 - Configuring modules with configuration /local/home/cta_test_bench/config/2018/20180201/config_12modules_SPE.NMC.xml 18:11 - NMC is in state NmcState.Configured and knows of 12 drawer(s) 18:11 - Found 0 PPS errors. 18:11 - Finished task "Configure NMC" 18:11 - Checking high voltages... 18:11 - Starting task "Check HV" 18:11 - Checking reference voltages against /local/home/cta_test_bench/config/2018/20180201/config_12modules_SPE.NMC.xml 18:11 - Done 18:11 - Found 12 drawer(s). Reference voltage is between 968.11 V and 1275.68 V. Actual voltage is between 968.68 V and 1277.34 V. 18:11 - Maximum difference between reference and actual voltage is 1.82 V 18:11 - Checking status of HVPA module in 12 drawer(s)... 18:11 - Checking status of HVPA channels in 12 drawer(s)... 18:11 - HV is stabilized in all channels. 18:11 - Finished task "Check HV" 18:12 - Starting NMC 18:12 - Clearing PPS error counters 18:12 - Checking status of calibration box... 18:12 - Calibration box is configured with 5 leds at a frequency of 10000.0 Hz and a voltage of 8.00 V 18:12 - Configuring TIB... 18:12 - Setting TIB forced mode to False 18:12 - Writing False to serveur.TIB.Forced.ForcedMode.ForcedMode_v 18:12 - Status: TibState.PpsStopped 18:12 - Alarms: AlarmVector.NoAlarm 18:12 - Writing 0.0 to serveur.TIB.ExternalDelay.ExternalDelay_v 18:12 - Setting TIB trigger mode to 0x8 = TriggerMask.SPhE 18:12 - Writing 8 to serveur.TIB.TriggerMode.ModeMask.ModeMask_v 18:12 - Writing 0 to serveur.TIB.InputsEnable.InputMask.InputMask_v 18:12 - Writing False to serveur.TIB.BUSY.DisableBusy.DisableBusy_v 18:12 - Writing 0.0 to serveur.TIB.BUSY.ExtraDelayBusy.ExtraDelayBusy_v 18:12 - Writing False to serveur.TIB.Throttler.DisableThrottlerBP.DisableThrottlerBP_v 18:12 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP50us.MaxTriggersBP50us_v 18:12 - Writing 255 to serveur.TIB.Throttler.MaxTriggersBP1ms.MaxTriggersBP1ms_v 18:12 - Status: TibState.PpsStopped 18:12 - Alarms: AlarmVector.NoAlarm 18:12 - Closing TIB connection to camera server 18:12 - Connecting TIB to camera server at 10.10.0.251:222 18:12 - Starting TIB... 18:12 - Status: TibState.PpsStopped 18:12 - Alarms: AlarmVector.NoAlarm 18:12 - Resetting run 18:12 - Wait for UCTS external trigger before enabling trigger... 18:12 - Status: TibState.Standby 18:12 - Alarms: AlarmVector.NoAlarm 18:12 - Status: TibState.Standby 18:12 - Alarms: AlarmVector.NoAlarm 18:12 - Status: TibState.CoutingPps 18:12 - Alarms: AlarmVector.NoAlarm 18:12 - Starting TIB triggers... 18:12 - Enabling trigger 18:12 - Status: TibState.Running 18:12 - Alarms: AlarmVector.NoAlarm INFO Scanning voltage of the calibration box from 8.000000 V to 16.010000 V INFO Setting LED mask to 0x0 INFO Configuring calibration box with leds=0x0 voltage=8.00 frequency=300.0/3 duration=0 width=1 lemo_out=True fiber1_out=True fiber2_out=False enabled=False INFO Starting flashes... INFO Stopping flashes... INFO Setting LED mask to 0x358 INFO Setting voltage to 8.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 8.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 8.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 8.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 9.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 9.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 9.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 9.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 10.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 10.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 10.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 10.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 11.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 11.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 11.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 11.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 12.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 12.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 12.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 12.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 13.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 13.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 13.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 13.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 14.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 14.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 14.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 14.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 15.000000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 15.250000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 15.500000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 15.750000 V INFO Starting flashes... INFO Stopping flashes... INFO Setting voltage to 16.000000 V INFO Starting flashes... INFO Stopping flashes... 18:25 - Stopping TIB... 18:25 - Status: TibState.Running 18:25 - Alarms: AlarmVector.NoAlarm 18:25 - Disabling trigger 18:25 - Status: TibState.RunStopped 18:25 - Alarms: AlarmVector.NoAlarm 18:25 - Disabling PPS 18:25 - Status: TibState.PpsStopped 18:25 - Alarms: AlarmVector.NoAlarm 18:25 - Closing TIB connection to camera server 18:26 - Stopping NMC 18:26 - Found 0 PPS errors. 18:26 - Status: TibState.PpsStopped 18:26 - Alarms: AlarmVector.NoAlarm 18:26 - Run duration: 0:13:31 18:26 - Local camera triggers: 0 18:26 - Slow control triggers: 0 18:26 - Single photo-electron triggers: 38230 18:26 - Calibration triggers: 0 18:26 - Software triggers from UCTS: 0 18:26 - Auto-pedestal triggers: 5276865 18:26 - Collected input triggers: 38230 18:26 - Busy triggers: 0 18:26 - Non-busy triggers sent to UCTS: 38230 18:26 - Camera event triggers sent to clusters: 38230 18:26 - Checking status of calibration box... 18:26 - Calibration box is configured with 5 leds at a frequency of 100.0 Hz and a voltage of 15.99 V